Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera

As an example, we generated new LAMP assays targeting drug resistance in V. cholerae and evaluated existing ones from the literature based on in silico target specificity and in vitro testing. Improvements in the design and testing of LAMP assays, with heightened target specificity and a simple analysis platform, increase utility for in-field applications. Overall, 9 of the 16 tested LAMP assays had positive signal through visual and computer vision-based detection methods developed here. Here we show LAMP assays tested on synthetic AMR gene targets for aph(6), varG, floR, qnrVC5, and almG, which allow for resistance to aminoglycosides, penicillins, carbapenems, phenicols, fluoroquinolones, and polymyxins respectively.

Authors

Institutions

Publication Details

Journal
BMC Bioinformatics
Published
2024-12-18
DOI
https://doi.org/10.1186/s12859-024-06001-3
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera

Shanmuga Sozhamannan, Nicholas Tolli, Bradley W. Abramson, Katharine Jennings et al.
2 citations
BMC Bioinformatics
Biosensors and Analytical Detection
0.37
article

Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera

Shanmuga Sozhamannan, Nicholas Tolli, Bradley W. Abramson, Katharine Jennings, Daniel Negrón, Gabrielle Melton, Stephanie Guertin, Bryan D. Necciai, Shipra Trivedi, David A. Ashford
article en
2 citations

Abstract

As an example, we generated new LAMP assays targeting drug resistance in V. cholerae and evaluated existing ones from the literature based on in silico target specificity and in vitro testing. Improvements in the design and testing of LAMP assays, with heightened target specificity and a simple analysis platform, increase utility for in-field applications. Overall, 9 of the 16 tested LAMP assays had positive signal through visual and computer vision-based detection methods developed here. Here we show LAMP assays tested on synthetic AMR gene targets for aph(6), varG, floR, qnrVC5, and almG, which allow for resistance to aminoglycosides, penicillins, carbapenems, phenicols, fluoroquinolones, and polymyxins respectively.

BMC BioinformaticsVol. 25(1)
Noblis (US), Stafford College (GB)
U.S. Department of Defense, Joint Program Executive Office for Chemical, Biological, Radiological and Nuclear Defense
Zero hunger
Openalex Percentile: Top 41%
Biosensors and Analytical Detection
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera — Shanmuga Sozhamannan, Nicholas Tolli, et al. · BMC Bioinformatics (2024) | TGRS Research Map | TGRS