[Application of modified percutaneous closure in the treatment of ventricular septal rupture after acute myocardial infarction].

<b>Objective:</b> To investigate the effect of modified percutaneous closure in the treatment of ventricular septal rupture. <b>Methods:</b> This study is a retrospective cohort study. Forty-four patients with ventricular septal rupture who underwent percutaneous closure at the Fuwai Central China Cardiovascular Hospital from December 2017 to October 2023 were included. According to the closure method, patients were divided into the modified group (11 cases) and the traditional group (33 cases). Surgical success was defined as successful placement of the occluder. The operation time, X-ray intake, sheath bending rate, incidence of ventricular fibrillation and pericardial tamponade, and postoperative residual shunt were compared between the two groups. <b>Results:</b> The age of the patients was (75.0±5.7) years, with 20 (45%) males. There were 3 cases of operation failure in the traditional group, while all patients in the modified group were successfully occluded. The procedure time in the modified group was shorter than that in the traditional group (40 (35, 45) min vs. 60 (50, 65)min, <i>P</i><0.001); X-ray dose intake was lower ((442.43±73.26)mGy vs. (784.45±247.78)mGy, <i>P</i><0.001). There was no occurrence of sheath bending in the modified group, while the incidence of sheath bending in the traditional surgery group was 46% (15/33), and the difference was statistically significant (<i>P</i>=0.017). Intraoperative ventricular fibrillation and pericardial tamponade occurred in 7 cases (21%) and 2 cases (6%) in the traditional group respectively, while none occurred in the modified group, but the differences between the groups were not statistically significant (both <i>P</i>>0.05). There was no significant difference in residual shunt between the two groups (3.6 (2.5, 4.3) mm vs. 4.0 (3.5, 4.5) mm,<i>P</i>=0.506). <b>Conclusion:</b> The procedure of modified ventricular septal rupture closure is more simplified, with a lower incidence ofventricular fibrillation and pericardial tamponade.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-12-24
DOI
https://doi.org/10.3760/cma.j.cn112148-20231201-00477
Primary Topic
Cardiac Structural Anomalies and Repair
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Application of modified percutaneous closure in the treatment of ventricular septal rupture after acute myocardial infarction].

Yu Han, Chuanyu Gao, Yahui Liu, Jinhua Zhang et al.
PubMed
Cardiac Structural Anomalies and Repair
article

[Application of modified percutaneous closure in the treatment of ventricular septal rupture after acute myocardial infarction].

Yu Han, Chuanyu Gao, Yahui Liu, Jinhua Zhang, Ben Liu, Jicheng Jiang, Z R Sun
article en

Abstract

<b>Objective:</b> To investigate the effect of modified percutaneous closure in the treatment of ventricular septal rupture. <b>Methods:</b> This study is a retrospective cohort study. Forty-four patients with ventricular septal rupture who underwent percutaneous closure at the Fuwai Central China Cardiovascular Hospital from December 2017 to October 2023 were included. According to the closure method, patients were divided into the modified group (11 cases) and the traditional group (33 cases). Surgical success was defined as successful placement of the occluder. The operation time, X-ray intake, sheath bending rate, incidence of ventricular fibrillation and pericardial tamponade, and postoperative residual shunt were compared between the two groups. <b>Results:</b> The age of the patients was (75.0±5.7) years, with 20 (45%) males. There were 3 cases of operation failure in the traditional group, while all patients in the modified group were successfully occluded. The procedure time in the modified group was shorter than that in the traditional group (40 (35, 45) min vs. 60 (50, 65)min, <i>P</i><0.001); X-ray dose intake was lower ((442.43±73.26)mGy vs. (784.45±247.78)mGy, <i>P</i><0.001). There was no occurrence of sheath bending in the modified group, while the incidence of sheath bending in the traditional surgery group was 46% (15/33), and the difference was statistically significant (<i>P</i>=0.017). Intraoperative ventricular fibrillation and pericardial tamponade occurred in 7 cases (21%) and 2 cases (6%) in the traditional group respectively, while none occurred in the modified group, but the differences between the groups were not statistically significant (both <i>P</i>>0.05). There was no significant difference in residual shunt between the two groups (3.6 (2.5, 4.3) mm vs. 4.0 (3.5, 4.5) mm,<i>P</i>=0.506). <b>Conclusion:</b> The procedure of modified ventricular septal rupture closure is more simplified, with a lower incidence ofventricular fibrillation and pericardial tamponade.

PubMedVol. 52(12)
Zhengzhou Central Hospital (CN)
Cardiac Structural Anomalies and Repair
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.