Fire Protection Systems, Life-Saving Facilities, and Fire Management in Depok City in 2020: A Case Study

Introduction: Hospital fire can result in greater casualties, injuries to patients or staff, and loss of property and equipment compared to fires in other types of building. This is attributed to the presence of a large number of vulnerable individuals, including those who are ill, disabled, pregnant, children, elderly, immunocompromised, on life support, or incapable of moving independently. This study aims to assess the implementation of the fire protection system, life-saving facilities, and fire management in Hospital X. Methods: This was a quantitative study on active fire protection system facilities, passive protection system facilities, live-saving facilities, and fire management as the subjects. Data were collected through observation, interviews, and document review, as well as a checklist and then analyzed by comparing the actual conditions with applicable standards and regulations. The final result was presented as the percentage compliance level and categorization according to the criteria established by the Research and Development Agency of the Public Works Department. Results: The active fire protection system presented a standard fulfillment rate of 53%, categorizing it as poor. The passive fire protection systems similarly demonstrated a poor fulfillment rate at 42%, while the life-saving facilities achieved a 66.7% fulfillment rate, placing them in the quite good category. Additionally, fire management attained an 81% fulfillment level, which falls under the good category. Conclusion: Hospital X has a good fire prevention approach with a standard fulfillment level of 60%.

Authors

Institutions

Publication Details

Journal
The Indonesian Journal of Occupational Safety and Health
Published
2024-12-12
DOI
https://doi.org/10.20473/ijosh.v13i3.2024.304-313
Citations
1
Primary Topic
Occupational Health and Safety Management
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fire Protection Systems, Life-Saving Facilities, and Fire Management in Depok City in 2020: A Case Study

Dadan Erwandi, Maura Wilona Andanari
1 citations
The Indonesian Journal of Occupational Safety and Health
Occupational Health and Safety Management
1.72
article

Fire Protection Systems, Life-Saving Facilities, and Fire Management in Depok City in 2020: A Case Study

Dadan Erwandi, Maura Wilona Andanari
article en
1 citations

Abstract

Introduction: Hospital fire can result in greater casualties, injuries to patients or staff, and loss of property and equipment compared to fires in other types of building. This is attributed to the presence of a large number of vulnerable individuals, including those who are ill, disabled, pregnant, children, elderly, immunocompromised, on life support, or incapable of moving independently. This study aims to assess the implementation of the fire protection system, life-saving facilities, and fire management in Hospital X. Methods: This was a quantitative study on active fire protection system facilities, passive protection system facilities, live-saving facilities, and fire management as the subjects. Data were collected through observation, interviews, and document review, as well as a checklist and then analyzed by comparing the actual conditions with applicable standards and regulations. The final result was presented as the percentage compliance level and categorization according to the criteria established by the Research and Development Agency of the Public Works Department. Results: The active fire protection system presented a standard fulfillment rate of 53%, categorizing it as poor. The passive fire protection systems similarly demonstrated a poor fulfillment rate at 42%, while the life-saving facilities achieved a 66.7% fulfillment rate, placing them in the quite good category. Additionally, fire management attained an 81% fulfillment level, which falls under the good category. Conclusion: Hospital X has a good fire prevention approach with a standard fulfillment level of 60%.

The Indonesian Journal of Occupational Safety and HealthVol. 13(3)
University of Indonesia (ID)
Ministry of Health of the Republic of Indonesia, Pan American Health Organization
Openalex Percentile: Top 12%
Occupational Health and Safety Management
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fire Protection Systems, Life-Saving Facilities, and Fire Management in Depok City in 2020: A Case Study — Dadan Erwandi, Maura Wilona Andanari · The Indonesian Journal of Occupational Safety and Health (2024) | TGRS Research Map | TGRS