Anterior Endolaser for Use With Flanged Intrascleral Haptic Fixation When Complicated by IOL Haptic Rotation or Dislocation

Purpose To describe a technique to address intraocular lens (IOL) complications associated with loss of haptic security at the optic–haptic junction. Methods Case series. Results The authors successfully used argon endolaser to secure the insertion and orientation of the haptics at the optic–haptic junction in three cases: one involving postoperative IOL tilt, the second as prophylaxis prior to performing intrascleral haptic fixation, and the third to stabilize the optic–haptic junction after spontaneous complete disinsertion followed by reinsertion of the dislocated haptic into the optic. Conclusions Argon endolaser may obviate the need for IOL exchange in certain cases of optic–haptic junction compromise in three-piece IOLs. [ Journal of Refractive Surgery Case Reports . 2024;4(4):e46–e50.]

Authors

Institutions

Publication Details

Journal
Journal of Refractive Surgery Case Reports
Published
2024-12-01
DOI
https://doi.org/10.3928/jrscr-20241122-01
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anterior Endolaser for Use With Flanged Intrascleral Haptic Fixation When Complicated by IOL Haptic Rotation or Dislocation

Jon D. Wender, Mitchell P. Weikert, Allison J. Chen, Anh Bui et al.
Journal of Refractive Surgery Case Reports
Intraocular Surgery and Lenses
article

Anterior Endolaser for Use With Flanged Intrascleral Haptic Fixation When Complicated by IOL Haptic Rotation or Dislocation

Jon D. Wender, Mitchell P. Weikert, Allison J. Chen, Anh Bui, M. Bowes Hamill
article en

Abstract

Purpose To describe a technique to address intraocular lens (IOL) complications associated with loss of haptic security at the optic–haptic junction. Methods Case series. Results The authors successfully used argon endolaser to secure the insertion and orientation of the haptics at the optic–haptic junction in three cases: one involving postoperative IOL tilt, the second as prophylaxis prior to performing intrascleral haptic fixation, and the third to stabilize the optic–haptic junction after spontaneous complete disinsertion followed by reinsertion of the dislocated haptic into the optic. Conclusions Argon endolaser may obviate the need for IOL exchange in certain cases of optic–haptic junction compromise in three-piece IOLs. [ Journal of Refractive Surgery Case Reports . 2024;4(4):e46–e50.]

Journal of Refractive Surgery Case ReportsVol. 4(4)
Mitchell College (US)
Openalex Percentile: Top 63%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Anterior Endolaser for Use With Flanged Intrascleral Haptic Fixation When Complicated by IOL Haptic Rotation or Dislocation — Jon D. Wender, Mitchell P. Weikert, et al. · Journal of Refractive Surgery Case Reports (2024) | TGRS Research Map | TGRS