Current Sharing Analysis and Optimization for Full-Δ Three-Phase Interleaved LLC Circuits
The three-phase interleaved LLC (TP-LLC) circuit can effectively increase the power capacity, power density, and transmission efficiency, reducing the current ripple of the converter. Compared to the TP-LLC, the full-Δ TP-LLC exhibits notable advantages of lower current stresses and smaller passive component parameters, but it suffers from poor three-phase current balancing. To address this issue, this paper constructs a current-sharing analysis model and summarizes its current imbalance characteristics. Based on this model, two methods of safe operating region and phase-shifting correction technique are proposed to mitigate the imbalance characteristics of the full-Δ; type TP-LLC circuit. Finally, a2-kW prototype was developed for this study, and both simulation and experimental results have validated the effectiveness of these two methods.
Authors
- Xiangke Li (ORCID: https://orcid.org/0000-0002-4063-9920)
- Xiliang Chen (ORCID: https://orcid.org/0000-0002-5689-8396)
- Xiaohua Wu (ORCID: https://orcid.org/0000-0002-3264-6215)
- Qingling Luo
- Xin Zhao (ORCID: https://orcid.org/0000-0003-2176-7537)
- Le Tian
Institutions
- Northwestern Polytechnical University (CN)
Publication Details
- Published
- 2024-11-08
- DOI
- https://doi.org/10.1109/isesc63657.2024.10785277
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00