Power Loss Evaluation of Fault Ride Through for Three-Phase Dual-Active Bridge DC-DC Converter

The three-phase dual-active bridge (DAB3) converter has drawn great attention due to the substantial demand for renewable energy. Because of the lack of natural zero-crossing points, short-circuit faults are the most severe faults in dc grids, and more attention must be given to the protection of dc grids. The space-vector-based asymmetrical duty-cycle control (SV-ADCC) method and FRT-Buck modulation, which do not require DC circuit breakers or additional semiconductor devices, are proposed for the fault ride-through (FRT) operation. This paper analyzes the power losses of IGBT modules in FRT-Buck modulation. The conduction and switching losses are calculated based on the parameter values provided in the manufacturer's datasheet. Additionally, the comparison between FRT-Buck modulation and SPS modulation under various condition is made to estimate the thermal design for different conditions.

Authors

Institutions

Publication Details

Published
2024-11-08
DOI
https://doi.org/10.1109/isesc63657.2024.10785291
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Loss Evaluation of Fault Ride Through for Three-Phase Dual-Active Bridge DC-DC Converter

Jingxin Hu, Zilong Zhou, Mingwei Lu
HVDC Systems and Fault Protection
article

Power Loss Evaluation of Fault Ride Through for Three-Phase Dual-Active Bridge DC-DC Converter

Jingxin Hu, Zilong Zhou, Mingwei Lu
article en

Abstract

The three-phase dual-active bridge (DAB3) converter has drawn great attention due to the substantial demand for renewable energy. Because of the lack of natural zero-crossing points, short-circuit faults are the most severe faults in dc grids, and more attention must be given to the protection of dc grids. The space-vector-based asymmetrical duty-cycle control (SV-ADCC) method and FRT-Buck modulation, which do not require DC circuit breakers or additional semiconductor devices, are proposed for the fault ride-through (FRT) operation. This paper analyzes the power losses of IGBT modules in FRT-Buck modulation. The conduction and switching losses are calculated based on the parameter values provided in the manufacturer's datasheet. Additionally, the comparison between FRT-Buck modulation and SPS modulation under various condition is made to estimate the thermal design for different conditions.

Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 79%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power Loss Evaluation of Fault Ride Through for Three-Phase Dual-Active Bridge DC-DC Converter — Jingxin Hu, Zilong Zhou, et al. · (2024) | TGRS Research Map | TGRS