Steady-State Operating Area Analysis and Full Unit-Circle Realization for Current Source Converter

Current source converter (CSC) with dc fault ride-through capability and low-cost advantages, is attracting lots of attention in high-voltage direct current (HVDC) and renewable energy conversion fields. The steady-state operating area (SSOA) of voltage source converter (VSC) should be designed to achieve the full unit-circle in some utility applications. It's based on proper design of main parameters. But in existing studies on CSC, its main parameters are designed mostly based on unit power factor operation, without considering the full unit-circle realization of SSOA. To fill this gap, first the ranges of key parameters are summarized and then used to derive analytical expressions of SSOA constraints in per unit system for CSC. Second, the conditions for main parameters to realize the full unit-circle SSOA are investigated, revealing the L-C filter parameters' effects on the feasible domain of the rated ac voltage. Finally, while the full unit-circle conditions are satisfied, the minimum capacitor voltage is chosen as the optimization objective in the parameters design. Then the optimized parameters in typical HVDC applications are acquired. It's found that the rated ac voltage designed is relatively high for practical applications, indicating further tradeoffs between full unit-circle SSOA and system cost.

Authors

Institutions

Publication Details

Published
2024-11-08
DOI
https://doi.org/10.1109/isesc63657.2024.10785354
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Steady-State Operating Area Analysis and Full Unit-Circle Realization for Current Source Converter

Zhaoqi Song, Xiaoguang Wei, Jinjun Liu, Ronghui An et al.
Advanced DC-DC Converters
article

Steady-State Operating Area Analysis and Full Unit-Circle Realization for Current Source Converter

Zhaoqi Song, Xiaoguang Wei, Jinjun Liu, Ronghui An, Yunhai Shan, Wenwen Zhang
article en

Abstract

Current source converter (CSC) with dc fault ride-through capability and low-cost advantages, is attracting lots of attention in high-voltage direct current (HVDC) and renewable energy conversion fields. The steady-state operating area (SSOA) of voltage source converter (VSC) should be designed to achieve the full unit-circle in some utility applications. It's based on proper design of main parameters. But in existing studies on CSC, its main parameters are designed mostly based on unit power factor operation, without considering the full unit-circle realization of SSOA. To fill this gap, first the ranges of key parameters are summarized and then used to derive analytical expressions of SSOA constraints in per unit system for CSC. Second, the conditions for main parameters to realize the full unit-circle SSOA are investigated, revealing the L-C filter parameters' effects on the feasible domain of the rated ac voltage. Finally, while the full unit-circle conditions are satisfied, the minimum capacitor voltage is chosen as the optimization objective in the parameters design. Then the optimized parameters in typical HVDC applications are acquired. It's found that the rated ac voltage designed is relatively high for practical applications, indicating further tradeoffs between full unit-circle SSOA and system cost.

North China Electric Power University (CN), Institute of High Energy Physics (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 79%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Steady-State Operating Area Analysis and Full Unit-Circle Realization for Current Source Converter — Zhaoqi Song, Xiaoguang Wei, et al. · (2024) | TGRS Research Map | TGRS