Protective Implant for the Femoral Neck in Osteoporosis Patients

This study proposes a new type of femoral neck reinforcement implant for patients suffering from osteoporosis. The aim of the implant is to prevent fractures of this part of the bone. Implant designs in six variants have been simulation-tested in two situations: a typical static load and a simulated dynamic load, in which the force was applied in a manner corresponding to a sideways fall. The tests were carried out for six different biocompatible materials, i.e., three polymeric and three titanium alloys from which the implants could be made. The obtained results tentatively demonstrated the validity of the proposed concept and allowed the design with the best properties to emerge. In addition, they showed that the use of a polymeric material, in particular polylactide, leads to a more substantial reduction in maximum stress values.

Authors

Institutions

Publication Details

Journal
Acta Physica Polonica A
Published
2024-10-01
DOI
https://doi.org/10.12693/aphyspola.146.585
Primary Topic
Bone and Joint Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protective Implant for the Femoral Neck in Osteoporosis Patients

Mi­chael Urban, Jacek Dziedzic, Szymon Cygan, I. Stencel
1 links
Acta Physica Polonica A
Bone and Joint Diseases
article

Protective Implant for the Femoral Neck in Osteoporosis Patients

Mi­chael Urban, Jacek Dziedzic, Szymon Cygan, I. Stencel
article en

Abstract

This study proposes a new type of femoral neck reinforcement implant for patients suffering from osteoporosis. The aim of the implant is to prevent fractures of this part of the bone. Implant designs in six variants have been simulation-tested in two situations: a typical static load and a simulated dynamic load, in which the force was applied in a manner corresponding to a sideways fall. The tests were carried out for six different biocompatible materials, i.e., three polymeric and three titanium alloys from which the implants could be made. The obtained results tentatively demonstrated the validity of the proposed concept and allowed the design with the best properties to emerge. In addition, they showed that the use of a polymeric material, in particular polylactide, leads to a more substantial reduction in maximum stress values.

Acta Physica Polonica AVol. 146(4)
Warsaw University of Technology (PL)
Openalex Percentile: Top 69%
Bone and Joint Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.