Study of Thermo‐Oxidative Aging of Fluorinated Gaskets (FKM) Used in Plate Heat Exchangers

Abstract Gaskets are sealing elements used in plate heat exchangers, which are subjected to aggressive conditions during service. In particular, the compression state, together alongside temperatures, can cause a premature deterioration of properties. To monitor and prevent such a situation, this study uses the TTS (time‐temperature superposition) method and Arrhenius to predict the lifetime of FKM gaskets. For this purpose, thermo‐oxidative aging is conducted at different temperatures for up to 6 months, monitoring compression set (CS) and Shore A hardness. The results indicate that the gasket can withstand periods of up to almost 300 days in service for an operating temperature of 140 °C.

Authors

Institutions

Publication Details

Journal
Macromolecular Symposia
Published
2024-12-01
DOI
https://doi.org/10.1002/masy.202400055
Primary Topic
Thermal and Kinetic Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Thermo‐Oxidative Aging of Fluorinated Gaskets (FKM) Used in Plate Heat Exchangers

Elias Luiz de Souza, Mateus de Sousa Zanzi, Gabriel Benedet Dutra, Rafael S. Ribeiro
Macromolecular Symposia
Thermal and Kinetic Analysis
article

Study of Thermo‐Oxidative Aging of Fluorinated Gaskets (FKM) Used in Plate Heat Exchangers

Elias Luiz de Souza, Mateus de Sousa Zanzi, Gabriel Benedet Dutra, Rafael S. Ribeiro
article en

Abstract

Abstract Gaskets are sealing elements used in plate heat exchangers, which are subjected to aggressive conditions during service. In particular, the compression state, together alongside temperatures, can cause a premature deterioration of properties. To monitor and prevent such a situation, this study uses the TTS (time‐temperature superposition) method and Arrhenius to predict the lifetime of FKM gaskets. For this purpose, thermo‐oxidative aging is conducted at different temperatures for up to 6 months, monitoring compression set (CS) and Shore A hardness. The results indicate that the gasket can withstand periods of up to almost 300 days in service for an operating temperature of 140 °C.

Macromolecular SymposiaVol. 413(6)
Universidade Federal de Santa Catarina (BR)
Petrobras
Openalex Percentile: Top 85%
Thermal and Kinetic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.