Pump start instability on a low head pump turbine and testing with partial deaeration

Abstract Since 2019 Iberdrola has had an interest in enabling pump operation of the Valparaiso hydropower plant. Iberdrola contacted Andritz, the original manufacturer of the machines, and a collaboration for that purpose was started. This powerplant was equipped with two pump turbine units in the 1980ies but pump operation has not been possible since strong vibrations occurred during pump commissioning in 1995. Therefore, the units had only been operated in turbine mode since then. In 2020 Iberdrola and Andritz performed a renewed pump start test with a fully rewatered machine. This again led to high vibrations during the initial phase of guide vane opening. Subsequently, guide vane flutter (self-excitation) was investigated as a potential cause of the vibrations but could not be established as the cause. Instead, it was found, that due to a transient effect, the machine entered the unstable part of the pump characteristic. Partial deaeration before guide vane opening during pump start was then considered as a solution and successfully tested in 2021.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2024-11-01
DOI
https://doi.org/10.1088/1755-1315/1411/1/012026
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pump start instability on a low head pump turbine and testing with partial deaeration

B Nennemann, Claire Prada, M Bergweiler
IOP Conference Series Earth and Environmental Science
Hydraulic and Pneumatic Systems
article

Pump start instability on a low head pump turbine and testing with partial deaeration

B Nennemann, Claire Prada, M Bergweiler
article en

Abstract

Abstract Since 2019 Iberdrola has had an interest in enabling pump operation of the Valparaiso hydropower plant. Iberdrola contacted Andritz, the original manufacturer of the machines, and a collaboration for that purpose was started. This powerplant was equipped with two pump turbine units in the 1980ies but pump operation has not been possible since strong vibrations occurred during pump commissioning in 1995. Therefore, the units had only been operated in turbine mode since then. In 2020 Iberdrola and Andritz performed a renewed pump start test with a fully rewatered machine. This again led to high vibrations during the initial phase of guide vane opening. Subsequently, guide vane flutter (self-excitation) was investigated as a potential cause of the vibrations but could not be established as the cause. Instead, it was found, that due to a transient effect, the machine entered the unstable part of the pump characteristic. Partial deaeration before guide vane opening during pump start was then considered as a solution and successfully tested in 2021.

IOP Conference Series Earth and Environmental ScienceVol. 1411(1)
Iberdrola (Spain) (ES), Andritz (Canada) (CA), Andritz (Switzerland) (CH)
Openalex Percentile: Top 48%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pump start instability on a low head pump turbine and testing with partial deaeration — B Nennemann, Claire Prada, et al. · IOP Conference Series Earth and Environmental Science (2024) | TGRS Research Map | TGRS