CFD Simulation of the turbine start-up of a pump-turbine with investigation of the usage of a porous domain for modelling very small guide vane angles

Abstract With increasing number of transient operations, such as start and stop procedures in pump-turbines, CFD simulations of these sequences have become more important to understand the occurring flow phenomena and evaluate their impact on the pump-turbines lifetime. In the present work, the numerical setup for transient CFD simulations is discussed and a CFD simulation of a turbine start-up using a 29 million node mesh and the SBES turbulence model is carried out. The results demonstrate reasonable accuracy when comparing the overall trends with the available measurement data. However, significant underestimation of torque fluctuations as well as draft tube pressure fluctuations during the initial phase of the start-up is observed. In a subsequent study, the modelling of very small guide vane angles by a porous domain is investigated. An analytical function for the loss coefficient of the porous domain is applied up to different threshold values of the guide vane angle. A guide vane angle of 1° is identified as the best option regarding accuracy and computational effort.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2024-11-01
DOI
https://doi.org/10.1088/1755-1315/1411/1/012053
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD Simulation of the turbine start-up of a pump-turbine with investigation of the usage of a porous domain for modelling very small guide vane angles

Stefan Riedelbauch, Max Zorn
IOP Conference Series Earth and Environmental Science
Cavitation Phenomena in Pumps
article

CFD Simulation of the turbine start-up of a pump-turbine with investigation of the usage of a porous domain for modelling very small guide vane angles

Stefan Riedelbauch, Max Zorn
article en

Abstract

Abstract With increasing number of transient operations, such as start and stop procedures in pump-turbines, CFD simulations of these sequences have become more important to understand the occurring flow phenomena and evaluate their impact on the pump-turbines lifetime. In the present work, the numerical setup for transient CFD simulations is discussed and a CFD simulation of a turbine start-up using a 29 million node mesh and the SBES turbulence model is carried out. The results demonstrate reasonable accuracy when comparing the overall trends with the available measurement data. However, significant underestimation of torque fluctuations as well as draft tube pressure fluctuations during the initial phase of the start-up is observed. In a subsequent study, the modelling of very small guide vane angles by a porous domain is investigated. An analytical function for the loss coefficient of the porous domain is applied up to different threshold values of the guide vane angle. A guide vane angle of 1° is identified as the best option regarding accuracy and computational effort.

IOP Conference Series Earth and Environmental ScienceVol. 1411(1)
University of Stuttgart (DE)
Affordable and clean energy
Openalex Percentile: Top 44%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.