Abstract In 2014, Andritz received a contract to refurbish six Francis turbines with a total capacity of 840 MW. During the commissioning of the first unit, unexpected vibrations occurred within a power range of 25 to 65 MW, and Andritz was requested to find a solution. Unsteady computational fluid dynamics CFD simulations, revealed that the vibrations originated from intermittently cavitating inter-blade vortices. Conventional solutions involving compressed air injection were rejected, leaving natural aeration as the only viable option. Andritz explored various options for natural aeration by CFD and later, by means of homologous model tests. The solution was able to accommodate suction heads of approximately 10 meters and consisted of a specialized runner cap, referred to as pumping cap, which allowed for natural aeration through the hollow turbine shaft. The cap was optimized using two-phase CFD, and once installed on the prototype, it demonstrated a reduction of aproximately 50% in the peak level of vibration and noise. This achievement fully satisfied the customer, leading to the acceptance of the machine.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2024-11-01
DOI
https://doi.org/10.1088/1755-1315/1411/1/012004
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation of vibrations caused by inter-blade vortices using pumping cap for natural aeration

J Disciullo, S Afara, B Nennemann
IOP Conference Series Earth and Environmental Science
Vibration and Dynamic Analysis
article

Mitigation of vibrations caused by inter-blade vortices using pumping cap for natural aeration

J Disciullo, S Afara, B Nennemann
article en

Abstract

Abstract In 2014, Andritz received a contract to refurbish six Francis turbines with a total capacity of 840 MW. During the commissioning of the first unit, unexpected vibrations occurred within a power range of 25 to 65 MW, and Andritz was requested to find a solution. Unsteady computational fluid dynamics CFD simulations, revealed that the vibrations originated from intermittently cavitating inter-blade vortices. Conventional solutions involving compressed air injection were rejected, leaving natural aeration as the only viable option. Andritz explored various options for natural aeration by CFD and later, by means of homologous model tests. The solution was able to accommodate suction heads of approximately 10 meters and consisted of a specialized runner cap, referred to as pumping cap, which allowed for natural aeration through the hollow turbine shaft. The cap was optimized using two-phase CFD, and once installed on the prototype, it demonstrated a reduction of aproximately 50% in the peak level of vibration and noise. This achievement fully satisfied the customer, leading to the acceptance of the machine.

IOP Conference Series Earth and Environmental ScienceVol. 1411(1)
TransCanada (Canada) (CA)
Openalex Percentile: Top 71%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mitigation of vibrations caused by inter-blade vortices using pumping cap for natural aeration — J Disciullo, S Afara, et al. · IOP Conference Series Earth and Environmental Science (2024) | TGRS Research Map | TGRS