Indoor air quality in the university classroom: An experiment and simulation analysis in a tropical climate

Abstract A comfortable classroom environment depends heavily on indoor air quality to maximise productivity and performance. This statement refers to the preliminary survey indicating that most university students spend 90% of their time inside buildings. Each day, between three and six hours are spent in the classroom. However, most classrooms today are equipped with AC units, which restrict air exchange. A major reason is the high temperatures, especially in tropical climates. Overly high CO 2 concentrations will have a negative effect on health. The purpose of this research is to identify the indoor air quality of Classroom A.202, Department of Architecture, Diponegoro University, focusing particularly on CO 2 concentrations. A combination of experiments and simulations is used in the method. For 10 minutes, an Air Quality Monitor and CONTAM simulation software were used to measure and simulate window openings and occupant movements. The results show that CO 2 concentration levels increase as occupants in a room increase and air circulation becomes obstructed. It was found that good air circulation can lower CO 2 levels, resulting in an optimal learning environment.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2024-12-01
DOI
https://doi.org/10.1088/1755-1315/1414/1/012013
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor air quality in the university classroom: An experiment and simulation analysis in a tropical climate

Dany Perwita Sari, Bangun IR Harsritanto, D R D Anugerah
1 citations
IOP Conference Series Earth and Environmental Science
Building Energy and Comfort Optimization
0.77
article

Indoor air quality in the university classroom: An experiment and simulation analysis in a tropical climate

Dany Perwita Sari, Bangun IR Harsritanto, D R D Anugerah
article en
1 citations

Abstract

Abstract A comfortable classroom environment depends heavily on indoor air quality to maximise productivity and performance. This statement refers to the preliminary survey indicating that most university students spend 90% of their time inside buildings. Each day, between three and six hours are spent in the classroom. However, most classrooms today are equipped with AC units, which restrict air exchange. A major reason is the high temperatures, especially in tropical climates. Overly high CO 2 concentrations will have a negative effect on health. The purpose of this research is to identify the indoor air quality of Classroom A.202, Department of Architecture, Diponegoro University, focusing particularly on CO 2 concentrations. A combination of experiments and simulations is used in the method. For 10 minutes, an Air Quality Monitor and CONTAM simulation software were used to measure and simulate window openings and occupant movements. The results show that CO 2 concentration levels increase as occupants in a room increase and air circulation becomes obstructed. It was found that good air circulation can lower CO 2 levels, resulting in an optimal learning environment.

IOP Conference Series Earth and Environmental ScienceVol. 1414(1)
Diponegoro University (ID)
Climate action
Openalex Percentile: Top 24%
Building Energy and Comfort Optimization
0.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.