Enhancing calibration accuracy with laser interferometry for high-resolution measuring systems

This paper presents an analysis of the measurement capability of laser interferometry for calibrating high-resolution measuring systems, focusing on potential errors that need to be carefully controlled to ensure adequate metrological traceability. The primary scientific research focus of our National Dimensional Metrology Laboratory is the development of metrological applications for industry, with ongoing improvements in calibration procedures for measuring machines and tools. Through a review of possible error sources, an innovative approach to reducing the most significant factors is proposed. This is specifically applied to the following calibration cases: field calibration of coordinate measuring machines, and laboratory calibration of precision probes and line scales. Instrumental and environmental errors can be effectively mitigated by using periodically calibrated laser interferometers in well-controlled air conditions, ensuring an uncertainty of 0.2 µm/m. Most geometrical errors can be minimized by precise adjustments to the interferometry and positioning systems, achieving an uncertainty of 0.3 µm/m. However, errors caused by temperature differences in the material along the measuring path remain the most influential. These arise due to the high expansion coefficient of the material and some uncertainty in its properties. After several hours of temperature stabilization, using three temperature sensors along the displacement range for software compensation, temperature differences still contribute significantly to measurement uncertainty. For example, the error is 0.5 µm/min in the case of line scale calibration and 1.1 µm/m for coordinate measuring machine calibration.

Authors

Publication Details

Journal
Advances in Production Engineering & Management
Published
2024-10-31
DOI
https://doi.org/10.14743/apem2024.3.514
Citations
5
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
1.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing calibration accuracy with laser interferometry for high-resolution measuring systems

Rok Klobučar, Bojan Ačko, Lucija Č. Lipuš
5 citations
Advances in Production Engineering & Management
Advanced Measurement and Metrology Techniques
1.06
article

Enhancing calibration accuracy with laser interferometry for high-resolution measuring systems

Rok Klobučar, Bojan Ačko, Lucija Č. Lipuš
article en
5 citations

Abstract

This paper presents an analysis of the measurement capability of laser interferometry for calibrating high-resolution measuring systems, focusing on potential errors that need to be carefully controlled to ensure adequate metrological traceability. The primary scientific research focus of our National Dimensional Metrology Laboratory is the development of metrological applications for industry, with ongoing improvements in calibration procedures for measuring machines and tools. Through a review of possible error sources, an innovative approach to reducing the most significant factors is proposed. This is specifically applied to the following calibration cases: field calibration of coordinate measuring machines, and laboratory calibration of precision probes and line scales. Instrumental and environmental errors can be effectively mitigated by using periodically calibrated laser interferometers in well-controlled air conditions, ensuring an uncertainty of 0.2 µm/m. Most geometrical errors can be minimized by precise adjustments to the interferometry and positioning systems, achieving an uncertainty of 0.3 µm/m. However, errors caused by temperature differences in the material along the measuring path remain the most influential. These arise due to the high expansion coefficient of the material and some uncertainty in its properties. After several hours of temperature stabilization, using three temperature sensors along the displacement range for software compensation, temperature differences still contribute significantly to measurement uncertainty. For example, the error is 0.5 µm/min in the case of line scale calibration and 1.1 µm/m for coordinate measuring machine calibration.

Advances in Production Engineering & ManagementVol. 19(3)
European Commission, Javna Agencija za Raziskovalno Dejavnost RS, Ministrstvo za Izobraževanje, Znanost in Šport, Urad Republike Slovenije za Meroslovje, European Regional Development Fund
Industry, innovation and infrastructure
Openalex Percentile: Top 25%
Advanced Measurement and Metrology Techniques
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.