The Suggested Electrode Number in Electrocardiographic Imaging for Identifying Atrial Fibrillation Drivers

Electrocardiographic imaging (ECGI) is expected to map the epicardial potential non-invasively and globally and identify the atrial fibrillation (AF) drivers, which may compensate for the imprecision and incompleteness of the current intracardiac catheter mapping for AF drivers.There is currently no uniform standard in ECGI for the selection of the ideal electrode number on the body surface.To determine the optimal number of body surface electrodes for identifying the AF driving source, we conducted a comparison of the relevance and accuracy of the reconstructed epicardial potentials in ECGI when the electrode configurations tested were 128, 112, 96, 80, 72, 64, 48, 32, 24, and 12.After reviewing and analyzing the results acquired from 10 individuals with paroxysmal or persistent AF, we discovered that for persistent AF, the recommended number of electrodes is 64 or more, whereas for paroxysmal AF, the minimum number of electrodes is 48.This finding can be used as a foundation for selecting the number of body surface electrodes in ECGI, hence enhancing the clinical application efficiency and usefulness of ECGI in identifying the driving source of AF.

Authors

Publication Details

Journal
Computing in cardiology
Published
2024-12-01
DOI
https://doi.org/10.22489/cinc.2024.002
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Suggested Electrode Number in Electrocardiographic Imaging for Identifying Atrial Fibrillation Drivers

Yadan Zhang, Jian Wu, Min Xiang, Yangyang Cui
Computing in cardiology
ECG Monitoring and Analysis
article

The Suggested Electrode Number in Electrocardiographic Imaging for Identifying Atrial Fibrillation Drivers

Yadan Zhang, Jian Wu, Min Xiang, Yangyang Cui
article en

Abstract

Electrocardiographic imaging (ECGI) is expected to map the epicardial potential non-invasively and globally and identify the atrial fibrillation (AF) drivers, which may compensate for the imprecision and incompleteness of the current intracardiac catheter mapping for AF drivers.There is currently no uniform standard in ECGI for the selection of the ideal electrode number on the body surface.To determine the optimal number of body surface electrodes for identifying the AF driving source, we conducted a comparison of the relevance and accuracy of the reconstructed epicardial potentials in ECGI when the electrode configurations tested were 128, 112, 96, 80, 72, 64, 48, 32, 24, and 12.After reviewing and analyzing the results acquired from 10 individuals with paroxysmal or persistent AF, we discovered that for persistent AF, the recommended number of electrodes is 64 or more, whereas for paroxysmal AF, the minimum number of electrodes is 48.This finding can be used as a foundation for selecting the number of body surface electrodes in ECGI, hence enhancing the clinical application efficiency and usefulness of ECGI in identifying the driving source of AF.

Computing in cardiologyVol. 51
Openalex Percentile: Top 57%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.