Does Skin Tone Affect Machine Learning Classification Accuracy Applied to Photoplethysmography Signals?

A recent UK report highlighted the fact that measurements of blood oxygenation using pulse oximeters may be inaccurate for patients with darker skin tones.The photoplethysmography signals collected by pulse oximeters and a multitude of wearable devices are often combined with machine learning to derive physiological parameters that may be useful for health monitoring.So it is natural to question whether machine learning accuracy when using photoplethysmography signals as input can also lead to inaccurate results for darker skin tones, particularly when a model may be trained on data from subjects with predominantly lighter skin tones.To test this, we chose a binary classification problem of classifying systolic blood pressure as high ( 140 mm Hg) or not high (< 140 mm Hg).We used the Aurora BP dataset which includes photoplethysmography signals, blood pressure readings and Fitzpatrick skin tone classification.We trained a model using only skin tone class 1 data (lightest skin tone) and then tested all the other skin tone data using this model.We found that the accuracy dropped for all the other skin tone classes.We then trained a model using data from all skin tones and the accuracy for the darker skin tones improved except class 5.

Authors

Publication Details

Journal
Computing in cardiology
Published
2024-12-01
DOI
https://doi.org/10.22489/cinc.2024.038
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does Skin Tone Affect Machine Learning Classification Accuracy Applied to Photoplethysmography Signals?

Philip J. Aston
2 citations
Computing in cardiology
Non-Invasive Vital Sign Monitoring
0.37
article

Does Skin Tone Affect Machine Learning Classification Accuracy Applied to Photoplethysmography Signals?

Philip J. Aston
article en
2 citations

Abstract

A recent UK report highlighted the fact that measurements of blood oxygenation using pulse oximeters may be inaccurate for patients with darker skin tones.The photoplethysmography signals collected by pulse oximeters and a multitude of wearable devices are often combined with machine learning to derive physiological parameters that may be useful for health monitoring.So it is natural to question whether machine learning accuracy when using photoplethysmography signals as input can also lead to inaccurate results for darker skin tones, particularly when a model may be trained on data from subjects with predominantly lighter skin tones.To test this, we chose a binary classification problem of classifying systolic blood pressure as high ( 140 mm Hg) or not high (< 140 mm Hg).We used the Aurora BP dataset which includes photoplethysmography signals, blood pressure readings and Fitzpatrick skin tone classification.We trained a model using only skin tone class 1 data (lightest skin tone) and then tested all the other skin tone data using this model.We found that the accuracy dropped for all the other skin tone classes.We then trained a model using data from all skin tones and the accuracy for the darker skin tones improved except class 5.

Computing in cardiologyVol. 51
European Commission, HORIZON EUROPE Framework Programme
Openalex Percentile: Top 42%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.