Lateral Behavior of Columns With High-Strength Steel Coiled Strip Confinement

This paper presents the experimental investigation of the behavior of square reinforced concrete columns with high-strength (100 ksi [690 MPa]) steel coiled strips as embedded confinement reinforcement under reversed-cyclic lateral loading and constant axial compression load. Six full-scale specimens (20 × 20 in. [508 × 508 mm] cross section) with the following vari¬ations were tested: confinement type (strip or reinforc¬ing bar), layout (hoops and ties, spirals), and reinforce-ment ratios. The strip-confined specimens had similar peak strengths as a specimen confined by reinforcing bar ties, and this strength exceeded analytical predic¬tions. The stiffness of the strip-confined specimens was greater than the reinforcing-bar-confined specimen. In accordance with the American Concrete Institute’s Acceptance Criteria for Moment Frames Based on Structural Testing (T1.1-01), all specimens met the cri¬terion that the lateral load at 3.5% drift was not below 75% of the peak. Strip-confined specimens demonstrat¬ed improved residual strength behavior relative to the reinforcing-bar-confined specimen. Overall, the study demonstrated the promise of steel strip confinement for reinforced concrete columns in seismic regions.

Authors

Publication Details

Journal
PCI Journal
Published
2024-12-16
DOI
https://doi.org/10.15554/pcij70.1-01
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral Behavior of Columns With High-Strength Steel Coiled Strip Confinement

Lee H. Pearson, Ashley P. Thrall, Yahya C. Kurama, Steven M. Barbachyn et al.
1 citations
PCI Journal
Structural Load-Bearing Analysis
0.26
article

Lateral Behavior of Columns With High-Strength Steel Coiled Strip Confinement

Lee H. Pearson, Ashley P. Thrall, Yahya C. Kurama, Steven M. Barbachyn, Shane Oh, Brad D. Weldon
article en
1 citations

Abstract

This paper presents the experimental investigation of the behavior of square reinforced concrete columns with high-strength (100 ksi [690 MPa]) steel coiled strips as embedded confinement reinforcement under reversed-cyclic lateral loading and constant axial compression load. Six full-scale specimens (20 × 20 in. [508 × 508 mm] cross section) with the following vari¬ations were tested: confinement type (strip or reinforc¬ing bar), layout (hoops and ties, spirals), and reinforce-ment ratios. The strip-confined specimens had similar peak strengths as a specimen confined by reinforcing bar ties, and this strength exceeded analytical predic¬tions. The stiffness of the strip-confined specimens was greater than the reinforcing-bar-confined specimen. In accordance with the American Concrete Institute’s Acceptance Criteria for Moment Frames Based on Structural Testing (T1.1-01), all specimens met the cri¬terion that the lateral load at 3.5% drift was not below 75% of the peak. Strip-confined specimens demonstrat¬ed improved residual strength behavior relative to the reinforcing-bar-confined specimen. Overall, the study demonstrated the promise of steel strip confinement for reinforced concrete columns in seismic regions.

PCI JournalVol. 70(1)
Openalex Percentile: Top 42%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.