Timing Performance With Broadcom Metal Trench Silicon Photomultipliers

Single photon time resolution (SPTR), photon detection efficiency (PDE), and correlated noise rate are important performance characteristics of modern silicon photomultipliers (SiPMs) in consideration of advances in time-of-flight positron emission tomography (TOF-PET). Commercially available Broadcom near-ultra-violet metal-trench (NUV-MT) SiPMs feature metal-filled trench technology to suppress optical crosstalk. We investigated the achievable SPTR and coincidence time resolution (CTR) of NUV-MT SiPMs with various sizes and scintillation crystals, employing low-noise high-frequency readout electronics. The achievable intrinsic SPTRs of 2×2, 4×4, and 6×6 mm<sup>2</sup> devices were estimated using a picosecond-pulse laser setup. 2- and 4-mm SiPMs were coupled with 2×2×3 mm<sup>3</sup> and 3×3×20 mm<sup>3</sup> LGSO and BGO crystals to assess achievable CTRs. The intrinsic SPTRs of 2-, 4-, and 6-mm SiPMs biased with 48 V were estimated to be 45, 55, and 137 ps in full-width at half-maximum (FWHM), respectively. The detector comprised a 2-mm SiPM and a 2×2×3 mm<sup>3</sup> BGO achieved 111 ps CTR FWHM. The results demonstrated a significant influence of superior SPTR of 2-mm SiPM for the Cherenkov event portion compared to scintillation-based events. The suppressed noise of NUV-MT enabled stable operation at high bias voltage, offering excellent SPTR and PDE for breakthroughs in the timing resolution of TOF-PET detectors.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2024-12-16
DOI
https://doi.org/10.1109/trpms.2024.3518479
Citations
7
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
4.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Timing Performance With Broadcom Metal Trench Silicon Photomultipliers

R. Heller, Woon‐Seng Choong, Seung‐Eun Lee, Joshua W. Cates
7 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Radiation Detection and Scintillator Technologies
4.25
article

Timing Performance With Broadcom Metal Trench Silicon Photomultipliers

R. Heller, Woon‐Seng Choong, Seung‐Eun Lee, Joshua W. Cates
article en
7 citations

Abstract

Single photon time resolution (SPTR), photon detection efficiency (PDE), and correlated noise rate are important performance characteristics of modern silicon photomultipliers (SiPMs) in consideration of advances in time-of-flight positron emission tomography (TOF-PET). Commercially available Broadcom near-ultra-violet metal-trench (NUV-MT) SiPMs feature metal-filled trench technology to suppress optical crosstalk. We investigated the achievable SPTR and coincidence time resolution (CTR) of NUV-MT SiPMs with various sizes and scintillation crystals, employing low-noise high-frequency readout electronics. The achievable intrinsic SPTRs of 2×2, 4×4, and 6×6 mm<sup>2</sup> devices were estimated using a picosecond-pulse laser setup. 2- and 4-mm SiPMs were coupled with 2×2×3 mm<sup>3</sup> and 3×3×20 mm<sup>3</sup> LGSO and BGO crystals to assess achievable CTRs. The intrinsic SPTRs of 2-, 4-, and 6-mm SiPMs biased with 48 V were estimated to be 45, 55, and 137 ps in full-width at half-maximum (FWHM), respectively. The detector comprised a 2-mm SiPM and a 2×2×3 mm<sup>3</sup> BGO achieved 111 ps CTR FWHM. The results demonstrated a significant influence of superior SPTR of 2-mm SiPM for the Cherenkov event portion compared to scintillation-based events. The suppressed noise of NUV-MT enabled stable operation at high bias voltage, offering excellent SPTR and PDE for breakthroughs in the timing resolution of TOF-PET detectors.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(4)
Lawrence Berkeley National Laboratory (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Affordable and clean energy
Openalex Percentile: Top 5%
Radiation Detection and Scintillator Technologies
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Timing Performance With Broadcom Metal Trench Silicon Photomultipliers — R. Heller, Woon‐Seng Choong, et al. · IEEE Transactions on Radiation and Plasma Medical Sciences (2024) | TGRS Research Map | TGRS