High-performance liquid chromatographic method for determination of voriconazole in pure and gel formulation

For routine measurement of Voriconazole (VZ) in a pure and gel formulation, a quick and accurate RP-HPLC technique with UV detection (254 nm) was developed. With a flow rate of 1.0 ml/min using a mobile phase that contained acetonitrile and water mixed 50:50, v/v. Internal standard approach was used for quantification. The method shows good linearity (correlation coefficient = 0.9999) with acceptable accuracy, precision and robustness. Three elements were taken into account to measure robustness. Flow rate, mobile phase composition, and pH all have an impact on the response, but only the flow rate which causes a reduction in the concentration of the drug-has a significant impact on the response. Analyst, equipment, and days were taken into consideration for a precision measurement. The analytical procedure had good precision, as seen by the %RSD which is found to be less than 2.0. The proposed method was straightforward, extremely sensitive, exact, and accurate, and it had a retention time of less than 4 minutes, indicating that it is appropriate for daily quality control.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-12-16
DOI
https://doi.org/10.1371/journal.pone.0315704
Citations
2
Primary Topic
Antifungal resistance and susceptibility
Type
article
Field-Weighted Citation Impact
0.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-performance liquid chromatographic method for determination of voriconazole in pure and gel formulation

Aisha Jabeen, Zubair Anwar, Samina Sheikh, Anwar Ejaz Beg et al.
2 citations
PLoS ONE
Antifungal resistance and susceptibility
0.78
article

High-performance liquid chromatographic method for determination of voriconazole in pure and gel formulation

Aisha Jabeen, Zubair Anwar, Samina Sheikh, Anwar Ejaz Beg, Sadaf Ibrahim, Mirza Tasawer Baig, Ambreen Huma
article en
2 citations

Abstract

For routine measurement of Voriconazole (VZ) in a pure and gel formulation, a quick and accurate RP-HPLC technique with UV detection (254 nm) was developed. With a flow rate of 1.0 ml/min using a mobile phase that contained acetonitrile and water mixed 50:50, v/v. Internal standard approach was used for quantification. The method shows good linearity (correlation coefficient = 0.9999) with acceptable accuracy, precision and robustness. Three elements were taken into account to measure robustness. Flow rate, mobile phase composition, and pH all have an impact on the response, but only the flow rate which causes a reduction in the concentration of the drug-has a significant impact on the response. Analyst, equipment, and days were taken into consideration for a precision measurement. The analytical procedure had good precision, as seen by the %RSD which is found to be less than 2.0. The proposed method was straightforward, extremely sensitive, exact, and accurate, and it had a retention time of less than 4 minutes, indicating that it is appropriate for daily quality control.

PLoS ONEVol. 19(12)
Baqai Medical University (PK), Ziauddin University (PK)
Clean water and sanitation
Openalex Percentile: Top 26%
Antifungal resistance and susceptibility
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-performance liquid chromatographic method for determination of voriconazole in pure and gel formulation — Aisha Jabeen, Zubair Anwar, et al. · PLoS ONE (2024) | TGRS Research Map | TGRS