Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations

Abstract Background In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations. The objective of this study was to estimate patient radiation doses based on SSDE and the water-equivalent diameter (D W ) as an effect tool for dose optimization in paediatric head CT at two facilities in Tamale Metropolis, in the northern region of Ghana. This is a preliminary retrospective study conducted on 57 paediatric patients (comprising 32 males and 25 females), aged newborns to 16 years old, who underwent head CT examinations . Patient head sizes were determined in terms D W , which was calculated by manual contouring the circumference of the CT images excluding the background to measure the region of interest (ROI) using the mid-slice axial CT images. SSDE was calculated as the product of CTDI vol and the size-specific conversion coefficients (CTDI vol, 16 to SSDE) obtained from the American Association of Physicists in Medicine (AAPM) Report 293. Results At facility ‘A’, the median SSDE values for patients, aged 3 months to 1 year, 1 to 6 years, and older than 6 years were 46.1 mGy, 39.6 mGy, and 48.2 mGy, respectively. The corresponding CTDI vol values were 42.3 mGy, 39.1 mGy, and 51.7 mGy. Facility ‘B’ reported median SSDE values of 36.0, 39.2, and 43.8 mGy, with corresponding CTDI vol values of 28.7, 39.8, and 46.9 mGy for the same age categories. For all age groups, the two facilities showed significant differences in SSDE values (44.72 mGy vs. 39.77 mGy, p = 0.009) and CTDI vol values (45.72 mGy vs. 40.60 mGy, p = 0.03). Some of the age group doses were up to 25.3% in CTDI vol and 25.8% in SSDE higher than those found in published data. Conclusions The SSDEs estimated showed significant variations between the two facilities, indicating a possible variability of scan protocols for paediatric head CT examinations. The SSDEs obtained in this study could be useful for optimization of paediatric routine head CT examinations.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2024-12-16
DOI
https://doi.org/10.1186/s43055-024-01396-8
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations

Abdul Nashirudeen Mumuni, Hamza Sulemana, Izre-deen Osman Mohammed Abubakari
1 links
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
article

Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations

Abdul Nashirudeen Mumuni, Hamza Sulemana, Izre-deen Osman Mohammed Abubakari
article en

Abstract

Abstract Background In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations. The objective of this study was to estimate patient radiation doses based on SSDE and the water-equivalent diameter (D W ) as an effect tool for dose optimization in paediatric head CT at two facilities in Tamale Metropolis, in the northern region of Ghana. This is a preliminary retrospective study conducted on 57 paediatric patients (comprising 32 males and 25 females), aged newborns to 16 years old, who underwent head CT examinations . Patient head sizes were determined in terms D W , which was calculated by manual contouring the circumference of the CT images excluding the background to measure the region of interest (ROI) using the mid-slice axial CT images. SSDE was calculated as the product of CTDI vol and the size-specific conversion coefficients (CTDI vol, 16 to SSDE) obtained from the American Association of Physicists in Medicine (AAPM) Report 293. Results At facility ‘A’, the median SSDE values for patients, aged 3 months to 1 year, 1 to 6 years, and older than 6 years were 46.1 mGy, 39.6 mGy, and 48.2 mGy, respectively. The corresponding CTDI vol values were 42.3 mGy, 39.1 mGy, and 51.7 mGy. Facility ‘B’ reported median SSDE values of 36.0, 39.2, and 43.8 mGy, with corresponding CTDI vol values of 28.7, 39.8, and 46.9 mGy for the same age categories. For all age groups, the two facilities showed significant differences in SSDE values (44.72 mGy vs. 39.77 mGy, p = 0.009) and CTDI vol values (45.72 mGy vs. 40.60 mGy, p = 0.03). Some of the age group doses were up to 25.3% in CTDI vol and 25.8% in SSDE higher than those found in published data. Conclusions The SSDEs estimated showed significant variations between the two facilities, indicating a possible variability of scan protocols for paediatric head CT examinations. The SSDEs obtained in this study could be useful for optimization of paediatric routine head CT examinations.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 55(1)
University for Development Studies (GH)
Clean water and sanitation
Openalex Percentile: Top 60%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.