External Factors Influence on Defects Detection by Scanning Contact Potentiometry

Scanning contact potentiometry (SCP) method was used to detect structural inhomogeneities in a welded joint under the application of heat and constant electric current. For this purpose, a special sample was prepared, welded by manual arc welding from two halves of X8CrNiTi18-10 (Chromium-Nickel-titanium stainless Steel) austenitic steel, each with dimensions of 200×110×13.5mm. After welding, welded sample was inspected using X-ray radiography. The sample was stored for five months at room temperature, and the sample surface was scanned using different scanning speed ranging from 0.36 to 1.8 mm/sec. It was found that when scanning speed was increased, the signal values remained the same. In another experiment, a constant electric current was passed through the sample from 0.01 to 0.1A. Applying current led to the excitation of weak structural inhomogeneities from the welding joint butt, although it was machined. While heat led to an increase in diagnostic signal amplitude.

Authors

Institutions

Publication Details

Journal
Annals of Dunarea de Jos University of Galati Fascicle XII Welding Equipment and Technology
Published
2024-12-13
DOI
https://doi.org/10.35219/awet.2024.05
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External Factors Influence on Defects Detection by Scanning Contact Potentiometry

V. I. Surin, Anas Alwaheba
Annals of Dunarea de Jos University of Galati Fascicle XII Welding Equipment and Technology
Thermography and Photoacoustic Techniques
article

External Factors Influence on Defects Detection by Scanning Contact Potentiometry

V. I. Surin, Anas Alwaheba
article en

Abstract

Scanning contact potentiometry (SCP) method was used to detect structural inhomogeneities in a welded joint under the application of heat and constant electric current. For this purpose, a special sample was prepared, welded by manual arc welding from two halves of X8CrNiTi18-10 (Chromium-Nickel-titanium stainless Steel) austenitic steel, each with dimensions of 200×110×13.5mm. After welding, welded sample was inspected using X-ray radiography. The sample was stored for five months at room temperature, and the sample surface was scanned using different scanning speed ranging from 0.36 to 1.8 mm/sec. It was found that when scanning speed was increased, the signal values remained the same. In another experiment, a constant electric current was passed through the sample from 0.01 to 0.1A. Applying current led to the excitation of weak structural inhomogeneities from the welding joint butt, although it was machined. While heat led to an increase in diagnostic signal amplitude.

Annals of Dunarea de Jos University of Galati Fascicle XII Welding Equipment and TechnologyVol. 35
Jordan Hospital (JO), National Research Nuclear University MEPhI (RU)
Russian Foundation for Basic Research
Affordable and clean energy
Openalex Percentile: Top 74%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.