O040 Investigating the effects of airflow signal filtering on non-invasively quantified estimates of flow limitation

Abstract Introduction We previously reported a method to estimate flow limitation (FL, range 0-~1) from the airflow signal recorded within a polysomnogram. This method utilised high quality nasal pressure signals, without high-pass (HP) filtering. However, many clinical recording systems implement HP filtering on airflow signals. We hypothesised that FL estimates would be adversely affected when airflow signals have HP filtering present. Methods Within our existing framework for estimating FL, we manipulated the airflow signal by applying digital HP filtering (Butterworth, 4th order) at commonly used cutoff frequencies (0.005, 0.01, 0.03, 0.1Hz). At each HP filter cutoff, performance was assessed at the breath-level (pooled, all patients) and patient-level (median, sleep only) using coefficient of determination (R²) and root mean squared error (RMSE) comparing FL estimates with HP filtering against reference data without HP filtering. Results In N=96 individuals, R² decreased while RMSE increased as HP filter cutoff increased. For HP filter cutoffs at 0.005, 0.01, 0.03 and 0.1Hz, breath-level R² was 0.923, 0.879, 0.740, and 0.483; while RMSE was 0.062, 0.079, 0.129, and 0.219, respectively. Similarly, patient-level R² was 0.994, 0.977, 0.843, and 0.738; while RMSE was 0.015, 0.030, 0.100, and 0.170. Discussion Increasing HP cutoff frequency resulted in a reduction of consistency of FL estimates when compared to those made using an unfiltered airflow signal. Further work including reference to ‘gold standard’ is required, however, in line with current AASM recommendation (“Direct current (DC) or ≤0.03Hz”), this study suggests HP filter cutoff frequency for nasal pressure should be minimised, preferably avoided.

Authors

Institutions

Publication Details

Journal
SLEEP Advances
Published
2024-10-01
DOI
https://doi.org/10.1093/sleepadvances/zpae070.040
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O040 Investigating the effects of airflow signal filtering on non-invasively quantified estimates of flow limitation

D Mann, Scott A. Sands, Philip I. Terrill, Eric Staykov
SLEEP Advances
Flow Measurement and Analysis
article

O040 Investigating the effects of airflow signal filtering on non-invasively quantified estimates of flow limitation

D Mann, Scott A. Sands, Philip I. Terrill, Eric Staykov
article en

Abstract

Abstract Introduction We previously reported a method to estimate flow limitation (FL, range 0-~1) from the airflow signal recorded within a polysomnogram. This method utilised high quality nasal pressure signals, without high-pass (HP) filtering. However, many clinical recording systems implement HP filtering on airflow signals. We hypothesised that FL estimates would be adversely affected when airflow signals have HP filtering present. Methods Within our existing framework for estimating FL, we manipulated the airflow signal by applying digital HP filtering (Butterworth, 4th order) at commonly used cutoff frequencies (0.005, 0.01, 0.03, 0.1Hz). At each HP filter cutoff, performance was assessed at the breath-level (pooled, all patients) and patient-level (median, sleep only) using coefficient of determination (R²) and root mean squared error (RMSE) comparing FL estimates with HP filtering against reference data without HP filtering. Results In N=96 individuals, R² decreased while RMSE increased as HP filter cutoff increased. For HP filter cutoffs at 0.005, 0.01, 0.03 and 0.1Hz, breath-level R² was 0.923, 0.879, 0.740, and 0.483; while RMSE was 0.062, 0.079, 0.129, and 0.219, respectively. Similarly, patient-level R² was 0.994, 0.977, 0.843, and 0.738; while RMSE was 0.015, 0.030, 0.100, and 0.170. Discussion Increasing HP cutoff frequency resulted in a reduction of consistency of FL estimates when compared to those made using an unfiltered airflow signal. Further work including reference to ‘gold standard’ is required, however, in line with current AASM recommendation (“Direct current (DC) or ≤0.03Hz”), this study suggests HP filter cutoff frequency for nasal pressure should be minimised, preferably avoided.

SLEEP AdvancesVol. 5(Supplement_1)
Brigham and Women's Hospital (US), Harvard University (US), The University of Queensland (AU), Circadian (United States) (US)
Openalex Percentile: Top 74%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.