P132 Feasibility and acceptability of switching from a previous-generation to a new-generation full-face mask for positive airway pressure therapy of sleep apnea using remote care

Abstract Introduction Mask selection could affect an individual’s experience with positive airway pressure (PAP) treatment for obstructive sleep apnea, but there is very limited data on the impact of switching to a different mask once established on PAP therapy. This study investigated the patient’s experience when switching from a previous-generation full-face mask (FFM) to a new-generation FFM via remote care. Methods A new FFM (AirFit F30i) was successfully fitted to 107 participants during video conferencing sessions. Participants completed online questionnaires on day 1, day 3, day 7, day 30 and day 90 after FFM switch to collect subjective feedback and quality of life data; objective PAP device data were also downloaded. Results Residual apnea-hypopnea index did not significantly differ from baseline at day 30 (0.2±1.1/h [p=0.142]) or day 90 (0.2±1.0/h [p=0.061]). Average daily usage was significantly increased from baseline at day 30 (+0.4±1.5 h/day [p=0.033]) but not day 90 (+0.2±1.4 h/day [p=0.216]). Functional Outcomes of Sleep Questionnaire (FOSQ-10) score was similar at baseline and day 90 (change from baseline to day 90: 0.43±2.57 [p=0.174]). Subjective ratings for comfort, seal, and usability of the new-generation FFM were significantly better than the predefined acceptability level. Rates of PAP-related side effects were generally acceptable. Discussion Remote management of mask change was associated with good outcomes in terms of objective device data and patient acceptability. This approach could be used to improve the overall therapy experience for individuals requiring a PAP therapy mask change for any reason.

Authors

Institutions

Publication Details

Journal
SLEEP Advances
Published
2024-10-01
DOI
https://doi.org/10.1093/sleepadvances/zpae070.214
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P132 Feasibility and acceptability of switching from a previous-generation to a new-generation full-face mask for positive airway pressure therapy of sleep apnea using remote care

Shreya Girish, Xiaodong Zhu, Adam Benjafield, Jeff Armitstead et al.
SLEEP Advances
Obstructive Sleep Apnea Research
article

P132 Feasibility and acceptability of switching from a previous-generation to a new-generation full-face mask for positive airway pressure therapy of sleep apnea using remote care

Shreya Girish, Xiaodong Zhu, Adam Benjafield, Jeff Armitstead, Emma L. Gray, Leslee Willes, Ross Deas, P Cheah, S Moodley, N Banodkar
article en

Abstract

Abstract Introduction Mask selection could affect an individual’s experience with positive airway pressure (PAP) treatment for obstructive sleep apnea, but there is very limited data on the impact of switching to a different mask once established on PAP therapy. This study investigated the patient’s experience when switching from a previous-generation full-face mask (FFM) to a new-generation FFM via remote care. Methods A new FFM (AirFit F30i) was successfully fitted to 107 participants during video conferencing sessions. Participants completed online questionnaires on day 1, day 3, day 7, day 30 and day 90 after FFM switch to collect subjective feedback and quality of life data; objective PAP device data were also downloaded. Results Residual apnea-hypopnea index did not significantly differ from baseline at day 30 (0.2±1.1/h [p=0.142]) or day 90 (0.2±1.0/h [p=0.061]). Average daily usage was significantly increased from baseline at day 30 (+0.4±1.5 h/day [p=0.033]) but not day 90 (+0.2±1.4 h/day [p=0.216]). Functional Outcomes of Sleep Questionnaire (FOSQ-10) score was similar at baseline and day 90 (change from baseline to day 90: 0.43±2.57 [p=0.174]). Subjective ratings for comfort, seal, and usability of the new-generation FFM were significantly better than the predefined acceptability level. Rates of PAP-related side effects were generally acceptable. Discussion Remote management of mask change was associated with good outcomes in terms of objective device data and patient acceptability. This approach could be used to improve the overall therapy experience for individuals requiring a PAP therapy mask change for any reason.

SLEEP AdvancesVol. 5(Supplement_1)
ResMed (Australia) (AU), Publicis Groupe (Germany) (DE)
Openalex Percentile: Top 68%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.