A Simple and Sensitive Imidazolium-Based Ionic Liquid-Modified Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Beta-Blockers in Human Plasma Samples

Beta-blockers (β-blockers) are broadly used to manage cardiac arrhythmia, which could increase in the upcoming years due to the aging population and the increase in the number of patients with cardiac burden. In the current work, a simple, sensitive, and reliable simultaneous determination of five β-blockers (acebutolol, pindolol, atenolol, nadolol, and oxprenolol) was accomplished by ionic liquid (IL)-modified reversed-phase liquid chromatography with ultraviolet detection. The chromatographic separation was achieved on a ZORBAX® SB-C18 column using a hybrid mobile phase consisting of 50 µg/mL 1-butyl-3-methylimidazolium chloride dissolved in 0.02 mol/L phosphate buffer (pH 3.5) and acetonitrile (70 : 30, v/v). The chromatographic measurements were performed by isocratic elution at a 1.0 mL/min flow rate, 230 nm wavelength, and 25°C column temperature. The current method was applied to human plasma matrices by direct injection of samples with a short analysis time of 12 min. Good linearity was achieved in the range of 3–500 ng/L for atenolol, acebutolol, and pindolol, 7–500 ng/L for acebutolol, and 10–500 ng/L for oxprenolol with a 0.999 coefficient of determination. The limit of detection/limit of quantification values were 1.04/3.00, 2.75/7.00, 1.03/3.00, 1.05/3.00, and 3.47/10.00 ng/L for atenolol, nadolol, acebutolol, pindolol, and oxprenolol, respectively. Results of intra-day and inter-day precision were found to be less than 2%. The sensitivity enhancement factors of analytes due to the addition of IL ranged between 9- and 41-fold higher than that achieved in the absence of IL. Therefore, the proposed method could be used as a simple and sensitive analytical method for routine clinical analysis of β-blockers with the presence of a small amount of IL.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1061934824701387
Citations
3
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple and Sensitive Imidazolium-Based Ionic Liquid-Modified Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Beta-Blockers in Human Plasma Samples

Naflaa A. Aldawsari, Hassan M. Albishri, Basmah H. Alshammari, Deia Abd El‐Hady
3 citations
Journal of Analytical Chemistry
Analytical Chemistry and Chromatography
0.72
article

A Simple and Sensitive Imidazolium-Based Ionic Liquid-Modified Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Beta-Blockers in Human Plasma Samples

Naflaa A. Aldawsari, Hassan M. Albishri, Basmah H. Alshammari, Deia Abd El‐Hady
article en
3 citations

Abstract

Beta-blockers (β-blockers) are broadly used to manage cardiac arrhythmia, which could increase in the upcoming years due to the aging population and the increase in the number of patients with cardiac burden. In the current work, a simple, sensitive, and reliable simultaneous determination of five β-blockers (acebutolol, pindolol, atenolol, nadolol, and oxprenolol) was accomplished by ionic liquid (IL)-modified reversed-phase liquid chromatography with ultraviolet detection. The chromatographic separation was achieved on a ZORBAX® SB-C18 column using a hybrid mobile phase consisting of 50 µg/mL 1-butyl-3-methylimidazolium chloride dissolved in 0.02 mol/L phosphate buffer (pH 3.5) and acetonitrile (70 : 30, v/v). The chromatographic measurements were performed by isocratic elution at a 1.0 mL/min flow rate, 230 nm wavelength, and 25°C column temperature. The current method was applied to human plasma matrices by direct injection of samples with a short analysis time of 12 min. Good linearity was achieved in the range of 3–500 ng/L for atenolol, acebutolol, and pindolol, 7–500 ng/L for acebutolol, and 10–500 ng/L for oxprenolol with a 0.999 coefficient of determination. The limit of detection/limit of quantification values were 1.04/3.00, 2.75/7.00, 1.03/3.00, 1.05/3.00, and 3.47/10.00 ng/L for atenolol, nadolol, acebutolol, pindolol, and oxprenolol, respectively. Results of intra-day and inter-day precision were found to be less than 2%. The sensitivity enhancement factors of analytes due to the addition of IL ranged between 9- and 41-fold higher than that achieved in the absence of IL. Therefore, the proposed method could be used as a simple and sensitive analytical method for routine clinical analysis of β-blockers with the presence of a small amount of IL.

Journal of Analytical ChemistryVol. 79(12)
Taif University (SA), King Abdulaziz University (SA), Taibah University (SA), University of Ha'il (SA), University of Jeddah (SA)
Openalex Percentile: Top 32%
Analytical Chemistry and Chromatography
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.