Development and Validation of a Simple, Precise, and Robust Reversed-Phase High-Performance Liquid Chromatography-Ultraviolet Method for the Determination of Polyvinylpyrrolidone in Adhesives

Polyvinylpyrrolidone (PVP) is available in a range of molecular weights and related viscosities that can be selected according to the desired application properties. A simple, accurate, and robust reversed-phase liquid chromatography method has been developed and subsequently validated for the estimation of polyvinylpyrrolidone K-90 in adhesive formulations. Separation and maximum response of the peak were obtained at UV a wavelength of 200 nm on a Zorbax Eclipse XDB C18 column. The limit of detection and limit of quantification of PVP were found to be 16.0 and 50.0 mg/L, respectively. The calibration curve showed good linearity over the concentration range of 50.0 to 1000.0 mg/L, with a correlation coefficient of 0.999. The proposed method was validated for specificity, linearity, accuracy, precision, robustness, and ruggedness, and successfully applied for the determination of PVP in glue samples.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1061934824701417
Citations
1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Simple, Precise, and Robust Reversed-Phase High-Performance Liquid Chromatography-Ultraviolet Method for the Determination of Polyvinylpyrrolidone in Adhesives

Kanchan Sunil Nautiyal, Anubhav Saxena, Sachin Gupta
1 citations
Journal of Analytical Chemistry
Analytical Methods in Pharmaceuticals
0.24
article

Development and Validation of a Simple, Precise, and Robust Reversed-Phase High-Performance Liquid Chromatography-Ultraviolet Method for the Determination of Polyvinylpyrrolidone in Adhesives

Kanchan Sunil Nautiyal, Anubhav Saxena, Sachin Gupta
article en
1 citations

Abstract

Polyvinylpyrrolidone (PVP) is available in a range of molecular weights and related viscosities that can be selected according to the desired application properties. A simple, accurate, and robust reversed-phase liquid chromatography method has been developed and subsequently validated for the estimation of polyvinylpyrrolidone K-90 in adhesive formulations. Separation and maximum response of the peak were obtained at UV a wavelength of 200 nm on a Zorbax Eclipse XDB C18 column. The limit of detection and limit of quantification of PVP were found to be 16.0 and 50.0 mg/L, respectively. The calibration curve showed good linearity over the concentration range of 50.0 to 1000.0 mg/L, with a correlation coefficient of 0.999. The proposed method was validated for specificity, linearity, accuracy, precision, robustness, and ruggedness, and successfully applied for the determination of PVP in glue samples.

Journal of Analytical ChemistryVol. 79(12)
Seva Mandir (IN)
Openalex Percentile: Top 48%
Analytical Methods in Pharmaceuticals
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.