Ultrasound-Assisted Preparation of Fe3O4@MoS2 for the Preconcentration of Chlorpromazine from Urine Samples Prior to Quantification by High-Performance Liquid Chromatography with Ultraviolet Detection

In this work, a magnetic porous material (Fe3O4@MoS2) was facilely prepared and applied for magnetic solid-phase extraction clean-up before the determination of chlorpromazine in urine samples via high-performance liquid chromatography with ultraviolet detection. Various key factors affecting the extraction and desorption recoveries, including the amount of adsorbent, extraction time, pH, sample volume, adsorption capacity, and desorption conditions, were systematically investigated. Under optimized conditions, the calibration curve was linear over a wide concentration range of 10.00–5000 ng/mL, with a correlation coefficient of 0.9997. The limit of detection was determined to be 3.2 μg/L. Besides, recoveries for spiked urine samples at three concentration levels ranged from 97.2 to 105.8%, and the enhancement factor was 48. These results demonstrate that the proposed method is efficient and economical for the determination of chlorpromazine at trace levels in urine samples.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1061934824701405
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound-Assisted Preparation of Fe3O4@MoS2 for the Preconcentration of Chlorpromazine from Urine Samples Prior to Quantification by High-Performance Liquid Chromatography with Ultraviolet Detection

Ou Sha, Xincheng Dai, Yunfan Wu, Xiaobing Chen et al.
Journal of Analytical Chemistry
Analytical chemistry methods development
article

Ultrasound-Assisted Preparation of Fe3O4@MoS2 for the Preconcentration of Chlorpromazine from Urine Samples Prior to Quantification by High-Performance Liquid Chromatography with Ultraviolet Detection

Ou Sha, Xincheng Dai, Yunfan Wu, Xiaobing Chen, Huiwen Li, Yuan Xu
article en

Abstract

In this work, a magnetic porous material (Fe3O4@MoS2) was facilely prepared and applied for magnetic solid-phase extraction clean-up before the determination of chlorpromazine in urine samples via high-performance liquid chromatography with ultraviolet detection. Various key factors affecting the extraction and desorption recoveries, including the amount of adsorbent, extraction time, pH, sample volume, adsorption capacity, and desorption conditions, were systematically investigated. Under optimized conditions, the calibration curve was linear over a wide concentration range of 10.00–5000 ng/mL, with a correlation coefficient of 0.9997. The limit of detection was determined to be 3.2 μg/L. Besides, recoveries for spiked urine samples at three concentration levels ranged from 97.2 to 105.8%, and the enhancement factor was 48. These results demonstrate that the proposed method is efficient and economical for the determination of chlorpromazine at trace levels in urine samples.

Journal of Analytical ChemistryVol. 79(12)
The First People’s Hospital of Lianyungang (CN)
Openalex Percentile: Top 78%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultrasound-Assisted Preparation of Fe3O4@MoS2 for the Preconcentration of Chlorpromazine from Urine Samples Prior to Quantification by High-Performance Liquid Chromatography with Ultraviolet Detection — Ou Sha, Xincheng Dai, et al. · Journal of Analytical Chemistry (2024) | TGRS Research Map | TGRS