Rapid Detection of Acetone in Exhaled Breath for the Diagnosis of Diabetes Mellitus

The analysis of exhaled breath represents a rapidly advancing field in noninvasive medical diagnostics. This method avoids invasive procedures and allows for repeated testing. Acetone in exhaled breath correlates with blood glucose levels and serves as a biomarker for diabetes. Implementing analytical systems in medical facilities for the detection of acetone in exhaled breath facilitates the timely diagnosis of pathological changes in blood glucose levels, promotes early diabetes diagnosis, and supports monitoring of therapeutic effectiveness. This study proposes a method for the rapid detection of acetone in exhaled breath using a mobile diagnostic complex based on microfluidic systems. The system includes a PIA gas microchromatograph with a thermochemical detector, a planar chromatography column, a thermostated sample collection system, and the selective capture of interfering components, all regulated by electric microvalves. Additionally, it includes an automatic dosing system with adjustable purging times, ranging from 0.1 to 5 s, and accompanying software. This procedure enables analyses within a diagnostically significant range of acetone concentrations (0.5–20 ppm) in exhaled breath for diabetes diagnosis. The total analysis time is 3 min, with a retention time of 60 s for acetone. We have tested the diagnostic complex, which allows the direct detection of acetone in exhaled breath. The capture and drying system shows no loss of the target substance and ensures the high reproducibility of the results, with deviations from the reference value not exceeding 10%. Field testing confirmed the data obtained on model mixtures. We recommend the developed mobile diagnostic complex with automatic programmable dosing and the method for the quantitative determination of acetone in exhaled breath (0.5–20 ppm) for use in clinical studies within medical institutions.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1061934824701430
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Detection of Acetone in Exhaled Breath for the Diagnosis of Diabetes Mellitus

О. В. Родинков, И. А. Платонов, И. Н. Колесниченко, В. И. Платонов et al.
3 citations
Journal of Analytical Chemistry
Advanced Chemical Sensor Technologies
0.55
article

Rapid Detection of Acetone in Exhaled Breath for the Diagnosis of Diabetes Mellitus

О. В. Родинков, И. А. Платонов, И. Н. Колесниченко, В. И. Платонов, Александр Сергеевич Брыксин, Asthik E. Margaryan, Дмитрий Леонидович Колесниченко
article en
3 citations

Abstract

The analysis of exhaled breath represents a rapidly advancing field in noninvasive medical diagnostics. This method avoids invasive procedures and allows for repeated testing. Acetone in exhaled breath correlates with blood glucose levels and serves as a biomarker for diabetes. Implementing analytical systems in medical facilities for the detection of acetone in exhaled breath facilitates the timely diagnosis of pathological changes in blood glucose levels, promotes early diabetes diagnosis, and supports monitoring of therapeutic effectiveness. This study proposes a method for the rapid detection of acetone in exhaled breath using a mobile diagnostic complex based on microfluidic systems. The system includes a PIA gas microchromatograph with a thermochemical detector, a planar chromatography column, a thermostated sample collection system, and the selective capture of interfering components, all regulated by electric microvalves. Additionally, it includes an automatic dosing system with adjustable purging times, ranging from 0.1 to 5 s, and accompanying software. This procedure enables analyses within a diagnostically significant range of acetone concentrations (0.5–20 ppm) in exhaled breath for diabetes diagnosis. The total analysis time is 3 min, with a retention time of 60 s for acetone. We have tested the diagnostic complex, which allows the direct detection of acetone in exhaled breath. The capture and drying system shows no loss of the target substance and ensures the high reproducibility of the results, with deviations from the reference value not exceeding 10%. Field testing confirmed the data obtained on model mixtures. We recommend the developed mobile diagnostic complex with automatic programmable dosing and the method for the quantitative determination of acetone in exhaled breath (0.5–20 ppm) for use in clinical studies within medical institutions.

Journal of Analytical ChemistryVol. 79(12)
St Petersburg University (RU), Samara National Research University (RU)
Good health and well-being
Openalex Percentile: Top 36%
Advanced Chemical Sensor Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.