Fabrication and in vivo testing of a sub-mm duckbill valve for hydrocephalus treatment

Hydrocephalus is characterized by the accumulation of excess cerebrospinal fluid (CSF) in the cranium due to an imbalance between production and absorption of CSF. The standard treatment involves the implantation of a shunt to divert excess CSF into the peritoneal cavity, but these shunts exhibit high failure rates over time. In pursuit of improved reliability and performance, this study proposes a miniaturized valve designed to mimic the natural one-way valve function of the arachnoid granulations and thereby replace the shunts. A benchtop testing setup was employed to characterize the behavior of the fabricated valve. Additionally, an animal study was conducted to assess the valve's in vivo performance. This involved the injection of saline into the lateral ventricle to elevate intracranial pressure (ICP), followed by the drainage of the saline through the valve inserted into the cisterna magna (CM) to reduce pressure. Our prototype features a silicone duckbill valve design combined with a silicone tube as an inlet. Through benchtop testing, the valve exhibited unidirectional flow with negligible reverse leakage, revealing that critical parameters such as the width of the fluid channel (W) and bill length (L) could be controlled to optimize valve performance. Notably, the valve configuration with W= 0.8mm and L < 0.5mm achieved the lowest cracking pressure (2.22 ± 0.07 mmHg) and outflow resistance (22.00 ± 0.70 mmHg/mL/min) within the low cracking pressure range of conventional shunts. Our observations of the in vivo test demonstrated that when untreated states, pressure differences from baseline to peak exceeded 20 mmHg due to the absence of drainage, resulting in sustained pressure elevation. Conversely, upon treating states by removing the clamp, pressure differences from baseline to peak remained below 5 mmHg, indicating effective drainage of injected saline through the valve. These promising results highlight the potential of the miniaturized duckbill valve as an alternative for ICP management in hydrocephalus, offering improved control and reliability compared to conventional shunting systems. Further research is required to evaluate the valve's performance as a chronic implant.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2024-12-13
DOI
https://doi.org/10.1038/s41378-024-00829-8
Citations
1
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and in vivo testing of a sub-mm duckbill valve for hydrocephalus treatment

Jennifer Blain Christen, Daniel Gulick, Yuna Jung
1 citations
Microsystems & Nanoengineering
Cerebrospinal fluid and hydrocephalus
0.27
article

Fabrication and in vivo testing of a sub-mm duckbill valve for hydrocephalus treatment

Jennifer Blain Christen, Daniel Gulick, Yuna Jung
article en
1 citations

Abstract

Hydrocephalus is characterized by the accumulation of excess cerebrospinal fluid (CSF) in the cranium due to an imbalance between production and absorption of CSF. The standard treatment involves the implantation of a shunt to divert excess CSF into the peritoneal cavity, but these shunts exhibit high failure rates over time. In pursuit of improved reliability and performance, this study proposes a miniaturized valve designed to mimic the natural one-way valve function of the arachnoid granulations and thereby replace the shunts. A benchtop testing setup was employed to characterize the behavior of the fabricated valve. Additionally, an animal study was conducted to assess the valve's in vivo performance. This involved the injection of saline into the lateral ventricle to elevate intracranial pressure (ICP), followed by the drainage of the saline through the valve inserted into the cisterna magna (CM) to reduce pressure. Our prototype features a silicone duckbill valve design combined with a silicone tube as an inlet. Through benchtop testing, the valve exhibited unidirectional flow with negligible reverse leakage, revealing that critical parameters such as the width of the fluid channel (W) and bill length (L) could be controlled to optimize valve performance. Notably, the valve configuration with W= 0.8mm and L < 0.5mm achieved the lowest cracking pressure (2.22 ± 0.07 mmHg) and outflow resistance (22.00 ± 0.70 mmHg/mL/min) within the low cracking pressure range of conventional shunts. Our observations of the in vivo test demonstrated that when untreated states, pressure differences from baseline to peak exceeded 20 mmHg due to the absence of drainage, resulting in sustained pressure elevation. Conversely, upon treating states by removing the clamp, pressure differences from baseline to peak remained below 5 mmHg, indicating effective drainage of injected saline through the valve. These promising results highlight the potential of the miniaturized duckbill valve as an alternative for ICP management in hydrocephalus, offering improved control and reliability compared to conventional shunting systems. Further research is required to evaluate the valve's performance as a chronic implant.

Microsystems & NanoengineeringVol. 10(1)
Arizona State University (US)
U.S. Department of Defense, Congressionally Directed Medical Research Programs, U.S. Army Medical Research Acquisition Activity
Clean water and sanitation
Openalex Percentile: Top 41%
Cerebrospinal fluid and hydrocephalus
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.