Workflow evaluation of environmental contamination with hazardous drugs during compounding and administration in an UK hospital

IntroductionExposure of healthcare workers to hazardous drugs may result in adverse health effects underscoring the importance of validating working procedures and safety precautions to minimise the risk. The objective was to monitor environmental contamination caused by the hazardous drug workflow: from drug vials, compounding process, to patient administration.MethodsSurface wipe samples were collected from potentially contaminated surfaces in the compounding department and in the administration department. The outside of drug vials, compounded syringes, bags, elastomeric pumps, and gloves used by the nurses for administration were also monitored. Stationary air samples were collected near the isolators and above the bench top. Personal air samples were collected from pharmacy technicians, pharmacists, and nurses. Monitoring was performed in three trials during two-months. Samples were analysed for cyclophosphamide, 5-fluorouracil, docetaxel, and paclitaxel using liquid chromatography tandem mass spectrometry.ResultsContamination was mainly found for 5-fluorouracil and cyclophosphamide on isolator surfaces, bench top, trays, and compounded products. Lower levels of contamination were measured in the administration department on trays, trolley arms and gloves of the nurses. Paclitaxel and docetaxel were incidentally detected. Air contamination was found for paclitaxel in the compounding department in one trial, and 5-fluorouracil was detected once in front of an isolator. Docetaxel was found in one air sample of a nurse.ConclusionsContamination was mainly found for 5-fluorouracil and cyclophosphamide on the products compounded in the isolators. Contamination was further spread along the workflow towards the administration department causing surfaces in between being contaminated too.

Authors

Institutions

Publication Details

Journal
Journal of Oncology Pharmacy Practice
Published
2024-12-13
DOI
https://doi.org/10.1177/10781552241285138
Citations
4
Primary Topic
Safe Handling of Antineoplastic Drugs
Type
article
Field-Weighted Citation Impact
6.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Workflow evaluation of environmental contamination with hazardous drugs during compounding and administration in an UK hospital

Paul J. M. Sessink, B. Barry, Karen Campbell, Lynda Cameron et al.
4 citations
Journal of Oncology Pharmacy Practice
Safe Handling of Antineoplastic Drugs
6.87
article

Workflow evaluation of environmental contamination with hazardous drugs during compounding and administration in an UK hospital

Paul J. M. Sessink, B. Barry, Karen Campbell, Lynda Cameron, Lala M. Dunbar, Tessa Kirkness
article en
4 citations

Abstract

IntroductionExposure of healthcare workers to hazardous drugs may result in adverse health effects underscoring the importance of validating working procedures and safety precautions to minimise the risk. The objective was to monitor environmental contamination caused by the hazardous drug workflow: from drug vials, compounding process, to patient administration.MethodsSurface wipe samples were collected from potentially contaminated surfaces in the compounding department and in the administration department. The outside of drug vials, compounded syringes, bags, elastomeric pumps, and gloves used by the nurses for administration were also monitored. Stationary air samples were collected near the isolators and above the bench top. Personal air samples were collected from pharmacy technicians, pharmacists, and nurses. Monitoring was performed in three trials during two-months. Samples were analysed for cyclophosphamide, 5-fluorouracil, docetaxel, and paclitaxel using liquid chromatography tandem mass spectrometry.ResultsContamination was mainly found for 5-fluorouracil and cyclophosphamide on isolator surfaces, bench top, trays, and compounded products. Lower levels of contamination were measured in the administration department on trays, trolley arms and gloves of the nurses. Paclitaxel and docetaxel were incidentally detected. Air contamination was found for paclitaxel in the compounding department in one trial, and 5-fluorouracil was detected once in front of an isolator. Docetaxel was found in one air sample of a nurse.ConclusionsContamination was mainly found for 5-fluorouracil and cyclophosphamide on the products compounded in the isolators. Contamination was further spread along the workflow towards the administration department causing surfaces in between being contaminated too.

Journal of Oncology Pharmacy PracticeVol. 32(1)
Edinburgh Napier University (GB), Western General Hospital (GB), County Administrative Board (SE)
Openalex Percentile: Top 3%
Safe Handling of Antineoplastic Drugs
6.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.