Kirigami Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement

Eyelid pressure is a crucial biomechanical parameter for ocular health and refractive status, yet measuring it poses challenges related to flexibility, sensitivity, and regional specificity. This study introduces a novel smart contact lens that incorporates kirigami designs and an iontronic capacitive sensing array to enhance flexibility and conformability. The unique structural composition of this device allows for precise and simultaneous monitoring of eyelid pressure in multiple regions with a high sensitivity and seamlessly fit across corneal curvatures. The efficacy of the sensor has been thoroughly confirmed through comprehensive evaluations in rabbits and porcine eyes, demonstrating improved conformity and sensitivity compared to conventional single-point sensors. Assessments have been conducted in various conditions, including under anesthesia and in awake states, as well as the deliberate alteration of intraocular pressure fluctuations, all affirming the exceptional accuracy in detecting eyelid pressure. We envision that the smart contact lens has the potential to revolutionize diagnosis and management of eyelid-related ocular diseases.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-12-13
DOI
https://doi.org/10.1021/acssensors.4c02361
Citations
4
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
2.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Kirigami Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement

Jinfang Wu, Ruihua Wei, Yunbiao Zhao, Songhao Chen et al.
4 citations
ACS Sensors
Ocular Surface and Contact Lens
2.17
article

Kirigami Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement

Jinfang Wu, Ruihua Wei, Yunbiao Zhao, Songhao Chen, Xiaoyu Zhao, Wen Chen, Lan Yang
article en
4 citations

Abstract

Eyelid pressure is a crucial biomechanical parameter for ocular health and refractive status, yet measuring it poses challenges related to flexibility, sensitivity, and regional specificity. This study introduces a novel smart contact lens that incorporates kirigami designs and an iontronic capacitive sensing array to enhance flexibility and conformability. The unique structural composition of this device allows for precise and simultaneous monitoring of eyelid pressure in multiple regions with a high sensitivity and seamlessly fit across corneal curvatures. The efficacy of the sensor has been thoroughly confirmed through comprehensive evaluations in rabbits and porcine eyes, demonstrating improved conformity and sensitivity compared to conventional single-point sensors. Assessments have been conducted in various conditions, including under anesthesia and in awake states, as well as the deliberate alteration of intraocular pressure fluctuations, all affirming the exceptional accuracy in detecting eyelid pressure. We envision that the smart contact lens has the potential to revolutionize diagnosis and management of eyelid-related ocular diseases.

ACS SensorsVol. 10(2)
Beijing Tongren Hospital (CN), Capital Medical University (CN), Peking University (CN), Wenzhou Medical University (CN), Affiliated Eye Hospital of Wenzhou Medical College (CN), Eye Center (SA), National Clinical Research (US), Institute of Ophthalmology (MX), Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Tianjin Medical University Eye Hospital (CN), State Key Laboratory of Nuclear Physics and Technology, Tianjin Medical University (CN)
Affordable and clean energy
Openalex Percentile: Top 11%
Ocular Surface and Contact Lens
2.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.