Performance Analysis of Chirped Graded Photonic Crystal Resonator for Biosensing Applications

In this manuscript, a chirped graded photonic crystal (PhC) resonator structure is optimized for biosensing applications. The proposed structure comprises a bilayer PhC with an aqueous defect layer, where the thickness grading within the material is introduced, considering alpha (α) as a grading parameter. The device performance is analytically evaluated using the finite element method (FEM). The impact of α, the resonator thickness, and the incidence angle on the device performance is analyzed. Further, the device’s ability to be used as a biosensor is evaluated, considering cholesterol as an analyte. The analytical results demonstrate an average sensitivity of 410 nm/RIU, a quality factor of 0.91 × 103, and a figure of merit (FOM) of 2.47 × 102RIU−1, showing 88.5% and 43% improvements in sensitivity and FOM compared to recently reported devices. The device’s superior sensing performance makes it suitable for medical and commercial applications, while the use of thickness grading addresses fabrication limitations, offering a robust framework for advanced photonic device design.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-12-13
DOI
https://doi.org/10.3390/photonics11121173
Citations
12
Primary Topic
Photonic Crystals and Applications
Type
article
Field-Weighted Citation Impact
4.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Chirped Graded Photonic Crystal Resonator for Biosensing Applications

Jasmine Saini, Amit Kumar Goyal, Ajay Kumar
12 citations
Photonics
Photonic Crystals and Applications
4.05
article

Performance Analysis of Chirped Graded Photonic Crystal Resonator for Biosensing Applications

Jasmine Saini, Amit Kumar Goyal, Ajay Kumar
article en
12 citations

Abstract

In this manuscript, a chirped graded photonic crystal (PhC) resonator structure is optimized for biosensing applications. The proposed structure comprises a bilayer PhC with an aqueous defect layer, where the thickness grading within the material is introduced, considering alpha (α) as a grading parameter. The device performance is analytically evaluated using the finite element method (FEM). The impact of α, the resonator thickness, and the incidence angle on the device performance is analyzed. Further, the device’s ability to be used as a biosensor is evaluated, considering cholesterol as an analyte. The analytical results demonstrate an average sensitivity of 410 nm/RIU, a quality factor of 0.91 × 103, and a figure of merit (FOM) of 2.47 × 102RIU−1, showing 88.5% and 43% improvements in sensitivity and FOM compared to recently reported devices. The device’s superior sensing performance makes it suitable for medical and commercial applications, while the use of thickness grading addresses fabrication limitations, offering a robust framework for advanced photonic device design.

PhotonicsVol. 11(12)
Jaypee Institute of Information Technology (IN), Manipal Academy of Higher Education (IN)
Openalex Percentile: Top 5%
Photonic Crystals and Applications
4.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Analysis of Chirped Graded Photonic Crystal Resonator for Biosensing Applications — Jasmine Saini, Amit Kumar Goyal, et al. · Photonics (2024) | TGRS Research Map | TGRS