On the Use of Tension Transition Zones for Kinematic and Compliance Performance Analysis of Wire-Actuated Continuum Robots

Abstract Wire-actuated/tendon-actuated mechanisms suffer from discontinuity in their performance measures stemming from the limitation of unilateral actuation due to tendon actuation (pull-only actuation). Using traditional Jacobian-based performance measures ignores these limitations and can underestimate the expected position/orientation (pose) uncertainty for a given design. In this paper, we put forth the notion of wire-tension transition zones, and we illustrate how these tension transition zones can be used to modify the definition of the traditional Jacobian when calculating the expected robot performance in terms of dexterity, end-effector pose uncertainty and compliance. We use wire-actuated continuum robots as an illustrative robot architecture. We compare the expected performance of three-wire versus four-wire designs while considering somewhat realistic design parameters drawn from surgical robotics as an application domain. The results of our simulation studies emphasize the importance of carefully using the reduced Jacobin with tension transition zones to capture the performance measure discontinuities due to wires/tendons going slack. Furthermore, the results show that the traditional approach underestimates the uncertainty in the position of the end-effector by as much as 50% (effects of joint-level uncertainty) and 206% (compliance performance analysis) in the case of a three-wire design alternative. We believe that this contribution supports medical robotic system designers in architecture selection and comparative design performance analysis while avoiding unpleasant surprises that would otherwise be encountered if traditional performance measures were used.

Authors

Institutions

Publication Details

Journal
Journal of Mechanisms and Robotics
Published
2024-12-13
DOI
https://doi.org/10.1115/1.4067432
Citations
2
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Use of Tension Transition Zones for Kinematic and Compliance Performance Analysis of Wire-Actuated Continuum Robots

Jared Lawson, Nabil Simaan, Maximilian E. Reese, Neel Shihora et al.
2 citations
Journal of Mechanisms and Robotics
Soft Robotics and Applications
0.37
article

On the Use of Tension Transition Zones for Kinematic and Compliance Performance Analysis of Wire-Actuated Continuum Robots

Jared Lawson, Nabil Simaan, Maximilian E. Reese, Neel Shihora, Paul M. Moubarak, Long Wang
article en
2 citations

Abstract

Abstract Wire-actuated/tendon-actuated mechanisms suffer from discontinuity in their performance measures stemming from the limitation of unilateral actuation due to tendon actuation (pull-only actuation). Using traditional Jacobian-based performance measures ignores these limitations and can underestimate the expected position/orientation (pose) uncertainty for a given design. In this paper, we put forth the notion of wire-tension transition zones, and we illustrate how these tension transition zones can be used to modify the definition of the traditional Jacobian when calculating the expected robot performance in terms of dexterity, end-effector pose uncertainty and compliance. We use wire-actuated continuum robots as an illustrative robot architecture. We compare the expected performance of three-wire versus four-wire designs while considering somewhat realistic design parameters drawn from surgical robotics as an application domain. The results of our simulation studies emphasize the importance of carefully using the reduced Jacobin with tension transition zones to capture the performance measure discontinuities due to wires/tendons going slack. Furthermore, the results show that the traditional approach underestimates the uncertainty in the position of the end-effector by as much as 50% (effects of joint-level uncertainty) and 206% (compliance performance analysis) in the case of a three-wire design alternative. We believe that this contribution supports medical robotic system designers in architecture selection and comparative design performance analysis while avoiding unpleasant surprises that would otherwise be encountered if traditional performance measures were used.

Journal of Mechanisms and RoboticsVol. 17(6)
Stevens Institute of Technology (US), Johnson & Johnson (United States) (US), Vanderbilt University (US), Shoreline Community College (US), University School of Nashville (US), Auris Health (United States) (US)
Vanderbilt University, Ethicon Endo-Surgery
Openalex Percentile: Top 42%
Soft Robotics and Applications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.