Biofluorometric Acetone Gas Sensor of Sub-ppbv Level Sensitivity

Acetone gas in exhaled breath and skin gas is produced when fatty acids are used as an energy source in the body. The selective and sensitive continuous measurement of acetone gas would be useful for the early screening of diabetes mellitus, a condition characterized by increased fatty acid metabolism. In particular, there is a growing need for acetone gas sensors that enable the wearable measurement of trace concentrations of acetone gas emitted through the skin. In this study, we improved the sensor's sensitivity by optimizing the fluorescence measurement system and flow cell of a previously developed biofluorometric acetone gas sensor (bio-sniffer) using secondary alcohol dehydrogenase. To evaluate the performance of the improved acetone bio-sniffer, we constructed a dilution system to prepare acetone gas at subparts per billion by volume (ppbv) levels and verified its accuracy using gas chromatography-mass spectrometry. As a result, the dilution system was able to prepare 0.1 ppbv of acetone gas with a coefficient of variation of 5%. The improved acetone bio-sniffer demonstrated quantitative characteristics in the concentration range of 0.5-1000 ppbv, with a lower limit of quantification that was 40 times better than that of the conventional acetone bio-sniffer. In the future, this system is expected to be used for continuous measurement of acetone gas released through the skin.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-12-13
DOI
https://doi.org/10.1021/acs.analchem.4c03816
Citations
6
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biofluorometric Acetone Gas Sensor of Sub-ppbv Level Sensitivity

Takahiro Arakawa, Koji Toma, Kumi Yokota, Kenta Ichikawa et al.
6 citations
Analytical Chemistry
Advanced Chemical Sensor Technologies
1.11
article

Biofluorometric Acetone Gas Sensor of Sub-ppbv Level Sensitivity

Takahiro Arakawa, Koji Toma, Kumi Yokota, Kenta Ichikawa, Naohiro Ishizuki, Yasuhiko Iwasaki, Kenta Iitani, Kohji Mitsubayashi, Yuka Matsuhashi
article en
6 citations

Abstract

Acetone gas in exhaled breath and skin gas is produced when fatty acids are used as an energy source in the body. The selective and sensitive continuous measurement of acetone gas would be useful for the early screening of diabetes mellitus, a condition characterized by increased fatty acid metabolism. In particular, there is a growing need for acetone gas sensors that enable the wearable measurement of trace concentrations of acetone gas emitted through the skin. In this study, we improved the sensor's sensitivity by optimizing the fluorescence measurement system and flow cell of a previously developed biofluorometric acetone gas sensor (bio-sniffer) using secondary alcohol dehydrogenase. To evaluate the performance of the improved acetone bio-sniffer, we constructed a dilution system to prepare acetone gas at subparts per billion by volume (ppbv) levels and verified its accuracy using gas chromatography-mass spectrometry. As a result, the dilution system was able to prepare 0.1 ppbv of acetone gas with a coefficient of variation of 5%. The improved acetone bio-sniffer demonstrated quantitative characteristics in the concentration range of 0.5-1000 ppbv, with a lower limit of quantification that was 40 times better than that of the conventional acetone bio-sniffer. In the future, this system is expected to be used for continuous measurement of acetone gas released through the skin.

Analytical ChemistryVol. 96(51)
Tokyo Medical and Dental University (JP), Tokyo University of Technology (JP), Shibaura Institute of Technology (JP), Institute of Science Tokyo (JP), Kansai University (JP)
Ministry of Education, Culture, Sports, Science and Technology, New Energy and Industrial Technology Development Organization, Japan Society for the Promotion of Science, ACT-X
Affordable and clean energy
Openalex Percentile: Top 24%
Advanced Chemical Sensor Technologies
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.