A method for determining the heat and mass transfer efficiency in a film cooling tower with intensified fill packs

A modified method of transfer units is developed for a countercurrent film cooling tower with a structured tubular packing with surface intensifiers in order to determine the thermal efficiency of the gas and liquid phases and the temperature of the cooled water at the output. The approach of presenting the number of transfer units, taking into account additional terms with reverse mixing coefficients is applied to indirectly consider the hydrodynamic structure of flows and a decrease in the heat and mass transfer efficiency, compared with the ideal displacement model. An experimental installation with a layout (column) of a Plexiglass cooling tower with a diameter of 200 mm and a height of 2 m is described. Experimental data for water cooling in a structured packing block in the form of a vertical bundle of tightly packed polyethylene pipes with a diameter of 0.05 m with an annular discretely structured surface roughness are presented. Generalized calculated empirical expressions for the drag of dry and irrigated pipes, as well as the dependence of the volumetric mass transfer coefficient on air velocity at different irrigation densities, are obtained. The parameters of expression of the modified number of transfer units are identified based on experimental data on thermal efficiency in the gas phase. As a result, the dependence of the thermal efficiency in the gas phase on the pressure and design characteristics of the structured packing is obtained taking into account the reverse mixing of the flows. Reverse mixing is shown to reduce thermal efficiency by 8 – 15 %, which must be taken into account in the calculations of film cooling towers. The calculation results for the SK-400 industrial cooling tower using the presented expressions are provided and the agreement of the thermal efficiency of the cooling tower with the calculation according to the proposed method is shown.

Authors

Institutions

Publication Details

Journal
Thermophysics and Aeromechanics
Published
2024-12-13
DOI
https://doi.org/10.1134/s0869864324030090
Citations
1
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A method for determining the heat and mass transfer efficiency in a film cooling tower with intensified fill packs

Е. А. Лаптева, А. Г. Лаптев
1 citations
Thermophysics and Aeromechanics
Nanofluid Flow and Heat Transfer
0.18
article

A method for determining the heat and mass transfer efficiency in a film cooling tower with intensified fill packs

Е. А. Лаптева, А. Г. Лаптев
article en
1 citations

Abstract

A modified method of transfer units is developed for a countercurrent film cooling tower with a structured tubular packing with surface intensifiers in order to determine the thermal efficiency of the gas and liquid phases and the temperature of the cooled water at the output. The approach of presenting the number of transfer units, taking into account additional terms with reverse mixing coefficients is applied to indirectly consider the hydrodynamic structure of flows and a decrease in the heat and mass transfer efficiency, compared with the ideal displacement model. An experimental installation with a layout (column) of a Plexiglass cooling tower with a diameter of 200 mm and a height of 2 m is described. Experimental data for water cooling in a structured packing block in the form of a vertical bundle of tightly packed polyethylene pipes with a diameter of 0.05 m with an annular discretely structured surface roughness are presented. Generalized calculated empirical expressions for the drag of dry and irrigated pipes, as well as the dependence of the volumetric mass transfer coefficient on air velocity at different irrigation densities, are obtained. The parameters of expression of the modified number of transfer units are identified based on experimental data on thermal efficiency in the gas phase. As a result, the dependence of the thermal efficiency in the gas phase on the pressure and design characteristics of the structured packing is obtained taking into account the reverse mixing of the flows. Reverse mixing is shown to reduce thermal efficiency by 8 – 15 %, which must be taken into account in the calculations of film cooling towers. The calculation results for the SK-400 industrial cooling tower using the presented expressions are provided and the agreement of the thermal efficiency of the cooling tower with the calculation according to the proposed method is shown.

Thermophysics and AeromechanicsVol. 31(3)
Kazan State Power Engineering University (RU)
Affordable and clean energy
Openalex Percentile: Top 50%
Nanofluid Flow and Heat Transfer
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A method for determining the heat and mass transfer efficiency in a film cooling tower with intensified fill packs — Е. А. Лаптева, А. Г. Лаптев · Thermophysics and Aeromechanics (2024) | TGRS Research Map | TGRS