Retrospective Clinical Outcomes of Keratoplasty Using Human Donor Corneas Preserved in Eusol-C Hypothermic Storage Medium

<b>Objective:</b> To evaluate the clinical outcomes of cornea transplantation (penetrating keratoplasty, Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, and deep anterior lamellar keratoplasty) using donor corneas stored in Eusol-C hypothermic storage medium compared to corneas stored in organ-culture. <b>Methods</b>: The clinical outcomes of 92 patients who underwent corneal transplantation with human donor corneas stored in Eusol-C medium at 2-8 °C were retrospectively evaluated. The control group consisted of 169 patients who received corneas organ-cultured at 31 °C. Donor age, sex, death-to-preservation time, and storage time were recorded. Endothelial cell (EC) density (ECD), EC mortality, and EC morphology scores were evaluated during storage in both groups. Complication rates, visual outcomes, and corneal transparency were monitored for up to six months. <b>Results</b>: The mean storage in Eusol-C time was 7.7 ± 2.5 days, while organ-culture time was 14.2 ± 4.0 days. In the Eusol-C group, ECD was 2398 ± 354 cells/mm<sup>2</sup>, with an average EC morphology score of 3.4 ± 0.7/4. Approximately 28% of the corneas in the Eusol-C group had no EC mortality. In the organ-culture group, ECD was 2256 ± 328 cells/mm<sup>2</sup>, with an average EC morphology score of 3.5 ± 0.5/4, and 42% were devoid of EC mortality. No complications, such as re-bubbling, were observed in both groups during surgery. Transparent corneas were achieved in 81.3% of the Eusol-C group the day after surgery. Mean corrected distance visual acuity (CDVA) at 3 and 6 months was 4.5 ± 4.0/10 and 5.4 ± 3.7/10 for the Eusol-C group and 5.0 ± 2.9/10 and 5.7 ± 2.8/10 for the organ-culture group, with no statistical differences observed between the groups. No graft failure was observed up to three months. Graft rejection occurred in the Eusol-C group and in the organ-culture group in, respectively, one and two cases at the six-month follow-up. <b>Conclusions</b>: Comparable surgical outcomes were achieved with donor corneas stored in both hypothermic Eusol-C and organ-culture media.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-12-13
DOI
https://doi.org/10.3390/jcm13247606
Citations
2
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrospective Clinical Outcomes of Keratoplasty Using Human Donor Corneas Preserved in Eusol-C Hypothermic Storage Medium

Rossella Anna Maria Colabelli Gisoldi, Gemma Lodato, Umberto Rodella, Giulio Pocobelli et al.
2 citations
Journal of Clinical Medicine
Corneal surgery and disorders
0.81
article

Retrospective Clinical Outcomes of Keratoplasty Using Human Donor Corneas Preserved in Eusol-C Hypothermic Storage Medium

Rossella Anna Maria Colabelli Gisoldi, Gemma Lodato, Umberto Rodella, Giulio Pocobelli, Claudio Gatto, Jana D’Amato Tóthová, Laura Giurgola, Augusto Pocobelli, Giacinta Buffon, Carlo Nucci
article en
2 citations

Abstract

<b>Objective:</b> To evaluate the clinical outcomes of cornea transplantation (penetrating keratoplasty, Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, and deep anterior lamellar keratoplasty) using donor corneas stored in Eusol-C hypothermic storage medium compared to corneas stored in organ-culture. <b>Methods</b>: The clinical outcomes of 92 patients who underwent corneal transplantation with human donor corneas stored in Eusol-C medium at 2-8 °C were retrospectively evaluated. The control group consisted of 169 patients who received corneas organ-cultured at 31 °C. Donor age, sex, death-to-preservation time, and storage time were recorded. Endothelial cell (EC) density (ECD), EC mortality, and EC morphology scores were evaluated during storage in both groups. Complication rates, visual outcomes, and corneal transparency were monitored for up to six months. <b>Results</b>: The mean storage in Eusol-C time was 7.7 ± 2.5 days, while organ-culture time was 14.2 ± 4.0 days. In the Eusol-C group, ECD was 2398 ± 354 cells/mm<sup>2</sup>, with an average EC morphology score of 3.4 ± 0.7/4. Approximately 28% of the corneas in the Eusol-C group had no EC mortality. In the organ-culture group, ECD was 2256 ± 328 cells/mm<sup>2</sup>, with an average EC morphology score of 3.5 ± 0.5/4, and 42% were devoid of EC mortality. No complications, such as re-bubbling, were observed in both groups during surgery. Transparent corneas were achieved in 81.3% of the Eusol-C group the day after surgery. Mean corrected distance visual acuity (CDVA) at 3 and 6 months was 4.5 ± 4.0/10 and 5.4 ± 3.7/10 for the Eusol-C group and 5.0 ± 2.9/10 and 5.7 ± 2.8/10 for the organ-culture group, with no statistical differences observed between the groups. No graft failure was observed up to three months. Graft rejection occurred in the Eusol-C group and in the organ-culture group in, respectively, one and two cases at the six-month follow-up. <b>Conclusions</b>: Comparable surgical outcomes were achieved with donor corneas stored in both hypothermic Eusol-C and organ-culture media.

Journal of Clinical MedicineVol. 13(24)
University of Rome Tor Vergata (IT), Azienda Ospedaliera San Giovanni Addolorata (IT)
Good health and well-being
Openalex Percentile: Top 24%
Corneal surgery and disorders
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.