Three Developments Related to ANSI/HPS Standard N13.56

Three topics related to ANSI/HPS Standard N13.56, Sampling and Monitoring Releases of Airborne Radioactivity in the Workplace, are discussed. First, due to the omission of consideration of the activity's half-life in the standard's continuous particulate air monitor (CPAM) quantitative method, it is possible for concentration estimates produced by that calculation to be underestimated. Second, the concentration estimate found in air grab sampling, as discussed in the standard, is not, as claimed, an average unless the activity is "long-lived" (negligible decay during sampling). It is nonetheless possible for this calculation to produce a concentration estimate that is not significantly different from the average, depending on both the half-life of the activity and the sampling time. Third, the issue of when to change the filter for the CPAM method is addressed.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-12-13
DOI
https://doi.org/10.1097/hp.0000000000001921
Primary Topic
Nuclear and radioactivity studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three Developments Related to ANSI/HPS Standard N13.56

William C. Evans
Health Physics
Nuclear and radioactivity studies
article

Three Developments Related to ANSI/HPS Standard N13.56

William C. Evans
article en

Abstract

Three topics related to ANSI/HPS Standard N13.56, Sampling and Monitoring Releases of Airborne Radioactivity in the Workplace, are discussed. First, due to the omission of consideration of the activity's half-life in the standard's continuous particulate air monitor (CPAM) quantitative method, it is possible for concentration estimates produced by that calculation to be underestimated. Second, the concentration estimate found in air grab sampling, as discussed in the standard, is not, as claimed, an average unless the activity is "long-lived" (negligible decay during sampling). It is nonetheless possible for this calculation to produce a concentration estimate that is not significantly different from the average, depending on both the half-life of the activity and the sampling time. Third, the issue of when to change the filter for the CPAM method is addressed.

Health PhysicsVol. 128(5)
Senseonics (United States) (US)
Decent work and economic growth
Openalex Percentile: Top 72%
Nuclear and radioactivity studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.