PETAT — an ASIC for simple and efficient readout of large PET scanners

Abstract Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read out, mostly by application specific integrated circuits (ASICs) containing amplification, noise reduction, hit finding, time stamping and amplitude measurement. Although each ASIC provides up to ≈ 64 channels, a large number of chips is required with the need for auxiliary electronic components like voltage regulators or FPGAs for control and data readout. The FPGAs in turn often require multiple supply voltages and configuration infrastructure, so that PCBs get complicated, cumbersome and power-hungry, in addition to the significant power requirement of the front-end ASICs. We address this issue in the latest generation of our PETA readout ASIC for SiPMs by a simplified control scheme and, in particular, by a hierarchical serial data readout which does not require any additional FPGA. In addition, it provides a time-sorted stream of hit data, allowing early on-detector data reduction and hit pre-processing like the removal of hits with no coincident partner. The simplicity of this readout facilitates a supply scheme where power/ground of multiple ASICs are connected in series instead of the standard parallel connection. This `serial-powering' approach can reduce supply current (while increasing overall supply voltage) so that voltage drop issues in the supply are alleviated.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-12-01
DOI
https://doi.org/10.1088/1748-0221/19/12/c12007
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PETAT — an ASIC for simple and efficient readout of large PET scanners

M. Ritzert, P. Fischer, Thomas Kerschenbauer
Journal of Instrumentation
Medical Imaging Techniques and Applications
article

PETAT — an ASIC for simple and efficient readout of large PET scanners

M. Ritzert, P. Fischer, Thomas Kerschenbauer
article en

Abstract

Abstract Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read out, mostly by application specific integrated circuits (ASICs) containing amplification, noise reduction, hit finding, time stamping and amplitude measurement. Although each ASIC provides up to ≈ 64 channels, a large number of chips is required with the need for auxiliary electronic components like voltage regulators or FPGAs for control and data readout. The FPGAs in turn often require multiple supply voltages and configuration infrastructure, so that PCBs get complicated, cumbersome and power-hungry, in addition to the significant power requirement of the front-end ASICs. We address this issue in the latest generation of our PETA readout ASIC for SiPMs by a simplified control scheme and, in particular, by a hierarchical serial data readout which does not require any additional FPGA. In addition, it provides a time-sorted stream of hit data, allowing early on-detector data reduction and hit pre-processing like the removal of hits with no coincident partner. The simplicity of this readout facilitates a supply scheme where power/ground of multiple ASICs are connected in series instead of the standard parallel connection. This `serial-powering' approach can reduce supply current (while increasing overall supply voltage) so that voltage drop issues in the supply are alleviated.

Journal of InstrumentationVol. 19(12)
Heidelberg University (DE)
Openalex Percentile: Top 60%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.