Experimental study on improving water management in proton exchange membrane fuel cells through intermittent forced hydrogen convection at the anode

• A supply method for intermittent forced hydrogen convection is proposed. • The hydrogen supply strategy is coupled with the purge strategy. • The voltage decay rate decreased by 41.56 % using this method. • Voltage stability over the duration of the purge was improved by 3.7 %. Proton exchange membrane fuel cells (PEMFCs) operating in the dead-end anode (DEA) mode are susceptible to flooding downstream of the channel, causing uneven water distribution and subsequent performance degradation. Therefore, this study introduces a novel bidirectional hydrogen supply and bidirectional purge (BHS-BP) mode. This mode requires only the addition of three solenoid valves and piping reconfiguration based on the DEA mode. This low-cost modification allowed any anode inlet or outlet to serve as a hydrogen supply or purge port, facilitating intermittent forced hydrogen convection by controlling the solenoid valves. This study tested both the proposed and DEA modes on an air-cooled open-cathode PEMFC stack. Results show that the proposed mode effectively enhanced water distribution uniformity, at 7A load current, when hydrogen is supplied downward along the channel for 6 s and upward for 12 s, the power enhancement reaches a maximum of 2.56 %. The average voltage decay rate for a single purge period is reduced from 0.947 mVs −1 to 0.913 mVs −1 , and the total voltage decay rate of the stack during long-time operation is significantly reduced from 0.243 mVs −1 to 0.142 mVs −1 , the Hydrogen utilization rate is increased by 1.259 %. Furthermore, the proposed mode improves the voltage output stability by 3.7 % during purge duration.

Authors

Institutions

Publication Details

Journal
Fuel
Published
2024-12-13
DOI
https://doi.org/10.1016/j.fuel.2024.134083
Citations
4
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on improving water management in proton exchange membrane fuel cells through intermittent forced hydrogen convection at the anode

Xiwen Deng, Jilin Lei, Minyuan Du, Yi Liu et al.
4 citations
Fuel
Fuel Cells and Related Materials
0.83
article

Experimental study on improving water management in proton exchange membrane fuel cells through intermittent forced hydrogen convection at the anode

Xiwen Deng, Jilin Lei, Minyuan Du, Yi Liu, Hua Yang
article en
4 citations

Abstract

• A supply method for intermittent forced hydrogen convection is proposed. • The hydrogen supply strategy is coupled with the purge strategy. • The voltage decay rate decreased by 41.56 % using this method. • Voltage stability over the duration of the purge was improved by 3.7 %. Proton exchange membrane fuel cells (PEMFCs) operating in the dead-end anode (DEA) mode are susceptible to flooding downstream of the channel, causing uneven water distribution and subsequent performance degradation. Therefore, this study introduces a novel bidirectional hydrogen supply and bidirectional purge (BHS-BP) mode. This mode requires only the addition of three solenoid valves and piping reconfiguration based on the DEA mode. This low-cost modification allowed any anode inlet or outlet to serve as a hydrogen supply or purge port, facilitating intermittent forced hydrogen convection by controlling the solenoid valves. This study tested both the proposed and DEA modes on an air-cooled open-cathode PEMFC stack. Results show that the proposed mode effectively enhanced water distribution uniformity, at 7A load current, when hydrogen is supplied downward along the channel for 6 s and upward for 12 s, the power enhancement reaches a maximum of 2.56 %. The average voltage decay rate for a single purge period is reduced from 0.947 mVs −1 to 0.913 mVs −1 , and the total voltage decay rate of the stack during long-time operation is significantly reduced from 0.243 mVs −1 to 0.142 mVs −1 , the Hydrogen utilization rate is increased by 1.259 %. Furthermore, the proposed mode improves the voltage output stability by 3.7 % during purge duration.

FuelVol. 384
Kunming University of Science and Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 26%
Fuel Cells and Related Materials
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.