A Bidirectional Isolated DC-to-DC Converter with Hybrid Control of Pulse Width Modulation and Pulse Frequency Modulation

This paper proposes a modified bidirectional isolated DC/DC converter with hybrid control, which can be applied to bidirectional power transfer between energy storage systems and DC microgrids. Batteries are usually applied to energy storage systems. The battery lifespan may be shortened if the converter has large current ripple during the battery charging process. The proposed topology consists of a CLLC converter and an interleaved buck converter. The first stage is an isolated full bridge CLLC converter, and the second stage is an interleaved buck converter with hybrid control of pulse width modulation (PWM) and pulse frequency modulation (PFM). Additionally, the proposed topology achieves zero voltage switching (ZVS) for all switches and reduces the output current ripple. The operational principles of bidirectional power flow in both directions are described in detail. Finally, a 1.5 kW experimental prototype, rated with a high side voltage of 380 V and low side voltage range of 40–58 V, was constructed and tested to investigate the system performance. The measured highest efficiency for the proposed converter is 90% in charging mode, and 94% in discharging mode.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-12-13
DOI
https://doi.org/10.3390/pr12122866
Citations
1
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Bidirectional Isolated DC-to-DC Converter with Hybrid Control of Pulse Width Modulation and Pulse Frequency Modulation

Chih‐Chiang Hua, Jian-Bin Lai
1 citations
Processes
Induction Heating and Inverter Technology
0.21
article

A Bidirectional Isolated DC-to-DC Converter with Hybrid Control of Pulse Width Modulation and Pulse Frequency Modulation

Chih‐Chiang Hua, Jian-Bin Lai
article en
1 citations

Abstract

This paper proposes a modified bidirectional isolated DC/DC converter with hybrid control, which can be applied to bidirectional power transfer between energy storage systems and DC microgrids. Batteries are usually applied to energy storage systems. The battery lifespan may be shortened if the converter has large current ripple during the battery charging process. The proposed topology consists of a CLLC converter and an interleaved buck converter. The first stage is an isolated full bridge CLLC converter, and the second stage is an interleaved buck converter with hybrid control of pulse width modulation (PWM) and pulse frequency modulation (PFM). Additionally, the proposed topology achieves zero voltage switching (ZVS) for all switches and reduces the output current ripple. The operational principles of bidirectional power flow in both directions are described in detail. Finally, a 1.5 kW experimental prototype, rated with a high side voltage of 380 V and low side voltage range of 40–58 V, was constructed and tested to investigate the system performance. The measured highest efficiency for the proposed converter is 90% in charging mode, and 94% in discharging mode.

ProcessesVol. 12(12)
National Yunlin University of Science and Technology (TW)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 49%
Induction Heating and Inverter Technology
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.