An effective transformer less 7 level inverter with optimized PID and buck boost controller for grid-connected PV systems

This research paper presents an effective transformer-less seven-level inverter with an optimized proportional-integral-derivative (PID) controller and buck-boost controller for grid-connected photovoltaic (PV) systems. The proposed model aims to achieve optimum power quality (PQ) in a hybrid power system integrating battery and PV. This is accomplished by utilizing a unified power quality conditioner (UPQC-PQ) with active and reactive power is developed, utilizing a hybrid metaheuristic algorithm named the honey badger algorithm (HBA) along with the equilibrium optimization algorithm (EOA), referred to as the honey badger equilibrium optimization (HBEO) algorithm. The PID controller in the proposed model is optimized using the HBEO algorithm, resulting in a highly efficient hybrid renewable energy system. By incorporating a 7-level multilevel inverter model with minimal switch usage (only 5 switches instead of 12), the proposed model ensures minimal switching losses. The proposed model is implemented and verified through the MATLAB/Simulink platform.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Power Engineering (IJAPE)
Published
2024-12-13
DOI
https://doi.org/10.11591/ijape.v14.i1.pp23-36
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An effective transformer less 7 level inverter with optimized PID and buck boost controller for grid-connected PV systems

Mohammad Haseeb Khan, B. Mangu, B. Mohan Rao
International Journal of Applied Power Engineering (IJAPE)
Microgrid Control and Optimization
article

An effective transformer less 7 level inverter with optimized PID and buck boost controller for grid-connected PV systems

Mohammad Haseeb Khan, B. Mangu, B. Mohan Rao
article en

Abstract

This research paper presents an effective transformer-less seven-level inverter with an optimized proportional-integral-derivative (PID) controller and buck-boost controller for grid-connected photovoltaic (PV) systems. The proposed model aims to achieve optimum power quality (PQ) in a hybrid power system integrating battery and PV. This is accomplished by utilizing a unified power quality conditioner (UPQC-PQ) with active and reactive power is developed, utilizing a hybrid metaheuristic algorithm named the honey badger algorithm (HBA) along with the equilibrium optimization algorithm (EOA), referred to as the honey badger equilibrium optimization (HBEO) algorithm. The PID controller in the proposed model is optimized using the HBEO algorithm, resulting in a highly efficient hybrid renewable energy system. By incorporating a 7-level multilevel inverter model with minimal switch usage (only 5 switches instead of 12), the proposed model ensures minimal switching losses. The proposed model is implemented and verified through the MATLAB/Simulink platform.

International Journal of Applied Power Engineering (IJAPE)Vol. 14(1)
Osmania University (IN)
Openalex Percentile: Top 73%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An effective transformer less 7 level inverter with optimized PID and buck boost controller for grid-connected PV systems — Mohammad Haseeb Khan, B. Mangu, et al. · International Journal of Applied Power Engineering (IJAPE) (2024) | TGRS Research Map | TGRS