MXene Nanoconfinement of SAM-Modified Molecularly Imprinted Electrochemical Biosensor for Point-of-Care Monitoring of Carcinoembryonic Antigen

The high rate of cancer worldwide and the heavy costs imposed on governments and humanity have always motivated researchers to develop point-of-care (POC) biosensors for easy diagnosis and monitoring of cancer treatment. Herein, we report on a label-free impedimetric biosensor based on Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> MXene and imprinted ortho-phenylenediamine (o-PD) for the detection of carcinoembryonic antigen (CEA), a biomarker for various cancers surveillance, especially colorectal cancer (CRC). Accordingly, MXene was drop-casted on the surface of a disposable silver electrode to increase the sensitivity and create high-energy nanoareas on the surface, which are usable for protein immobilization and detection. A self-assembled monolayer (SAM) was exploited for oriented CEA immobilization on the MXene-modified electrode. The monomer-protein interaction and successful protein removal were confirmed by molecular docking and atomic force microscopy (AFM) investigations to evaluate the quality of the fabricated molecularly imprinted polymer (MIP). Also, the role of MXene in increasing the electrical field inside the nanoareas was simulated using COMSOL Multiphysics software. A suitable limit of detection (9.41 ng/mL), an appropriate linear range of detection (10 to 100 ng/mL) in human serum, and a short detection time (10 min) resulted from the use of SAM/MIP next to MXene. This biosensor presented outstanding repeatability (97.60%) and reproducibility (98.61%). Moreover, acceptable accuracy (between 93.04 and 116.04%) in clinical serum samples was obtained compared with immunoassay results, indicating the high potential of our biosensor for real sample analysis. This biomimetic and disposable sensor provides a cost-effective method for facile and POC monitoring of cancer patients during treatment.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-12-13
DOI
https://doi.org/10.1021/acssensors.4c02420
Citations
23
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
2.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MXene Nanoconfinement of SAM-Modified Molecularly Imprinted Electrochemical Biosensor for Point-of-Care Monitoring of Carcinoembryonic Antigen

Laleh Shariati, John F. Presley, Mohsen Rabbani, Fahimeh Ghasemi et al.
23 citations
ACS Sensors
MXene and MAX Phase Materials
2.69
article

MXene Nanoconfinement of SAM-Modified Molecularly Imprinted Electrochemical Biosensor for Point-of-Care Monitoring of Carcinoembryonic Antigen

Laleh Shariati, John F. Presley, Mohsen Rabbani, Fahimeh Ghasemi, Marziye Hadian, Alireza Sanati
article en
23 citations

Abstract

The high rate of cancer worldwide and the heavy costs imposed on governments and humanity have always motivated researchers to develop point-of-care (POC) biosensors for easy diagnosis and monitoring of cancer treatment. Herein, we report on a label-free impedimetric biosensor based on Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> MXene and imprinted ortho-phenylenediamine (o-PD) for the detection of carcinoembryonic antigen (CEA), a biomarker for various cancers surveillance, especially colorectal cancer (CRC). Accordingly, MXene was drop-casted on the surface of a disposable silver electrode to increase the sensitivity and create high-energy nanoareas on the surface, which are usable for protein immobilization and detection. A self-assembled monolayer (SAM) was exploited for oriented CEA immobilization on the MXene-modified electrode. The monomer-protein interaction and successful protein removal were confirmed by molecular docking and atomic force microscopy (AFM) investigations to evaluate the quality of the fabricated molecularly imprinted polymer (MIP). Also, the role of MXene in increasing the electrical field inside the nanoareas was simulated using COMSOL Multiphysics software. A suitable limit of detection (9.41 ng/mL), an appropriate linear range of detection (10 to 100 ng/mL) in human serum, and a short detection time (10 min) resulted from the use of SAM/MIP next to MXene. This biosensor presented outstanding repeatability (97.60%) and reproducibility (98.61%). Moreover, acceptable accuracy (between 93.04 and 116.04%) in clinical serum samples was obtained compared with immunoassay results, indicating the high potential of our biosensor for real sample analysis. This biomimetic and disposable sensor provides a cost-effective method for facile and POC monitoring of cancer patients during treatment.

ACS SensorsVol. 10(2)
Isfahan University of Medical Sciences (IR), Cardiovascular Institute Hospital (JP), University of Isfahan (IR), Biosensor (Italy) (IT), Advanced Tissue (United States) (US), Advanced Systems & Technologies (United States) (US), Biosensor Research Center, McGill University (CA)
Isfahan University of Medical Sciences
Openalex Percentile: Top 6%
MXene and MAX Phase Materials
2.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.