Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults

HVDC systems with high voltage and direct current are suitable for reducing electricity losses, during transmission over long distances. However, HVDC lines have the highest probability of failure within a system and can be damaged by different faults or lightning strikes. This paper presents a transient circuit model for the practical Egypt-Saudi Arabia link. The transient potential at different points along the line is calculated under different magnitudes and shapes of lightning strokes. "Additionally, the extent of transient overvoltages at the rectifier station due to shifts in lightning strike locations has been estimated. Furthermore, overvoltage distributions are examined caused by lightning strikes on a real ± 500 kV hybrid HVDC TL-Cableare examined. To prevent national disasters and maintain safe national ratios of electrical production, particularly in the case of hybrid HVDC TL-Cable faults, an analysis of different AC/DC faults in the hybrid HVDC TL-Cable is also presented. This study is based on an equivalent electrical model using Power Systems Computer-Aided Design (PSCAD) software. It was discovered that severe voltages appear at the rectifier station when 50 kAlightning stroke with 1.2 μ sec front time, and 350 μ sectail time hits the TL. Moreover, overvoltages are reduced by about 58% in hybrid HVDC TL-Cable. Also, surge arresters at rectifier stations reduce overvoltages by approximately 95%. Ultimately, DC pole-to-ground faults are more serious than other types of faults and can cause massive overcurrent in the system, potentially damaging the rectifier station.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-12-13
DOI
https://doi.org/10.1371/journal.pone.0313229
Citations
1
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults

Marwa Abdallah, Abdelrahman Said, Mohamed Galal
1 citations
PLoS ONE
Lightning and Electromagnetic Phenomena
0.33
article

Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults

Marwa Abdallah, Abdelrahman Said, Mohamed Galal
article en
1 citations

Abstract

HVDC systems with high voltage and direct current are suitable for reducing electricity losses, during transmission over long distances. However, HVDC lines have the highest probability of failure within a system and can be damaged by different faults or lightning strikes. This paper presents a transient circuit model for the practical Egypt-Saudi Arabia link. The transient potential at different points along the line is calculated under different magnitudes and shapes of lightning strokes. "Additionally, the extent of transient overvoltages at the rectifier station due to shifts in lightning strike locations has been estimated. Furthermore, overvoltage distributions are examined caused by lightning strikes on a real ± 500 kV hybrid HVDC TL-Cableare examined. To prevent national disasters and maintain safe national ratios of electrical production, particularly in the case of hybrid HVDC TL-Cable faults, an analysis of different AC/DC faults in the hybrid HVDC TL-Cable is also presented. This study is based on an equivalent electrical model using Power Systems Computer-Aided Design (PSCAD) software. It was discovered that severe voltages appear at the rectifier station when 50 kAlightning stroke with 1.2 μ sec front time, and 350 μ sectail time hits the TL. Moreover, overvoltages are reduced by about 58% in hybrid HVDC TL-Cable. Also, surge arresters at rectifier stations reduce overvoltages by approximately 95%. Ultimately, DC pole-to-ground faults are more serious than other types of faults and can cause massive overcurrent in the system, potentially damaging the rectifier station.

PLoS ONEVol. 19(12)
Benha University (EG)
Climate action
Openalex Percentile: Top 32%
Lightning and Electromagnetic Phenomena
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults — Marwa Abdallah, Abdelrahman Said, et al. · PLoS ONE (2024) | TGRS Research Map | TGRS