X-ray image target recognition and model lightweight deployment

Aiming at the constraints of computing power and storage resources of embedded devices, this paper puts forward an improved model lightweight scheme, mainly introducing model distillation and model quantization methods. After L2 loss knowledge distillation experiment based on intermediate features, the accuracy of YOLOv5s model is improved by 1.6%. Through asymmetric quantization experiment of PTQ INT8, the speed is improved by nearly 2.6 times when the model accuracy is only 2.3%, which meets the demand of real-time reasoning. After the quantitative perceptual training, the speed of the model is increased by 1.8 times with a loss of only 1.4%. The improved lightweight model is deployed in embedded devices, and its performance is tested. Under the condition that the accuracy of the original model is 97% on RK3588S, the reasoning speed is increased by 2.6 times.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1117/12.3047883
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-ray image target recognition and model lightweight deployment

Le Yu, Zihao Zhang, Tongyu Liu
Radiomics and Machine Learning in Medical Imaging
article

X-ray image target recognition and model lightweight deployment

Le Yu, Zihao Zhang, Tongyu Liu
article en

Abstract

Aiming at the constraints of computing power and storage resources of embedded devices, this paper puts forward an improved model lightweight scheme, mainly introducing model distillation and model quantization methods. After L2 loss knowledge distillation experiment based on intermediate features, the accuracy of YOLOv5s model is improved by 1.6%. Through asymmetric quantization experiment of PTQ INT8, the speed is improved by nearly 2.6 times when the model accuracy is only 2.3%, which meets the demand of real-time reasoning. After the quantitative perceptual training, the speed of the model is increased by 1.8 times with a loss of only 1.4%. The improved lightweight model is deployed in embedded devices, and its performance is tested. Under the condition that the accuracy of the original model is 97% on RK3588S, the reasoning speed is increased by 2.6 times.

National Engineering Research Center of Electromagnetic Radiation Control Materials (CN)
Openalex Percentile: Top 60%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.