A nasal-thermistor based study for continuous monitoring of breathing rate and apnea detection

The proposed study discusses a low-cost respiration rate detection system for continuous health monitoring. The significance of this study relies on the fact that the envisaged system can detect high and low ventilation alongside normal breathing conditions. Moreover, the above system can detect apnea as well. This study employs a thermistor attached to commonly available nebulization mask for primary transduction. The temperature difference between inhaled and exhaled air induces resistance changes in the thermistor, which further changes the output voltage across the above sensor in a potential divider network. Various amplification and filtering techniques are employed to extract a respiratory bio-signal of reasonable quality. A quasi-digital signal corresponding to this bio-signal is obtained. Thus, the respiratory rate can be inferred by measuring the time period of the above-mentioned quasi-digital pulse. The accuracy of the proposed system as a respiratory monitor was verified and compared with the help of a reference bio-instrument. Moreover, the study was conducted in a group of fifteen volunteers of various age groups. The maximum error in measuring RR was less than 1 bpm.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/spices62143.2024.10779923
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A nasal-thermistor based study for continuous monitoring of breathing rate and apnea detection

C. S. Anoop, Thomaskutty Mathew
1 citations
Non-Invasive Vital Sign Monitoring
0.18
article

A nasal-thermistor based study for continuous monitoring of breathing rate and apnea detection

C. S. Anoop, Thomaskutty Mathew
article en
1 citations

Abstract

The proposed study discusses a low-cost respiration rate detection system for continuous health monitoring. The significance of this study relies on the fact that the envisaged system can detect high and low ventilation alongside normal breathing conditions. Moreover, the above system can detect apnea as well. This study employs a thermistor attached to commonly available nebulization mask for primary transduction. The temperature difference between inhaled and exhaled air induces resistance changes in the thermistor, which further changes the output voltage across the above sensor in a potential divider network. Various amplification and filtering techniques are employed to extract a respiratory bio-signal of reasonable quality. A quasi-digital signal corresponding to this bio-signal is obtained. Thus, the respiratory rate can be inferred by measuring the time period of the above-mentioned quasi-digital pulse. The accuracy of the proposed system as a respiratory monitor was verified and compared with the help of a reference bio-instrument. Moreover, the study was conducted in a group of fifteen volunteers of various age groups. The maximum error in measuring RR was less than 1 bpm.

Indian Institute of Space Science and Technology (IN)
Openalex Percentile: Top 50%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.