Real-Time Detection of Solid and Liquid Contaminants in Natural Gas Streams Using Microwave Sensing Technology

Abstract The production and transportation of high-quality natural gas, that is free of liquid/solid contaminants, is critical to fulfilling the increasing global demand of this commodity. Despite several mitigation strategies from natural gas producers and distributors, liquid and solid contaminants are still commonly found within natural gas pipelines. As such, a need exists for real-time detection of these contaminants, within natural gas pipelines, in order to determine contaminant sources and reduce contaminant quantities. In this study, an in-line, non-perturbing, real-time, microwave-based contaminants sensing technology was developed and tested at a natural gas test facility located in Alberta, Canada. The contaminants detector was installed on DN150 pipe and tested over a gas velocity range of 1.3–13.2 m/s. First, glass oxide particles were intermittently injected into the gas stream immediately upstream of the detector. Two different glass oxide particles were tested with particle diameter ranges of 44–88 μm and 88–149μm. Second, liquid contaminant, in the form of compressor lubrication oil, was atomized into the gas stream immediately upstream of the detector. Three types of atomizing nozzles were used in conjunction with liquid injection pumps to test liquid injection rates in the range of 0.07–0.7 L/min. Liquid and solid contaminants were successfully detected using the standard deviation of in-phase and quadrature baseband voltage measurements from the contaminants detector. This paper quantitatively evaluates the solid/liquid contaminants detection performance of this detector in the context of natural gas pipeline applications.

Authors

Institutions

Publication Details

Journal
Volume 3: Operations, Monitoring, and Maintenance; Materials and Joining
Published
2024-09-23
DOI
https://doi.org/10.1115/ipc2024-133876
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Detection of Solid and Liquid Contaminants in Natural Gas Streams Using Microwave Sensing Technology

Mohammed Saif ur Rahman, Mohamed Alshehhi, K. K. Botros, Nicholas Chan et al.
1 citations
Volume 3: Operations, Monitoring, and Maintenance; Materials and Joining
Advanced Chemical Sensor Technologies
0.18
article

Real-Time Detection of Solid and Liquid Contaminants in Natural Gas Streams Using Microwave Sensing Technology

Mohammed Saif ur Rahman, Mohamed Alshehhi, K. K. Botros, Nicholas Chan, Keith Leong, Khaled Al‐Wahedi, Mohamed A. Abou‐Khousa
article en
1 citations

Abstract

Abstract The production and transportation of high-quality natural gas, that is free of liquid/solid contaminants, is critical to fulfilling the increasing global demand of this commodity. Despite several mitigation strategies from natural gas producers and distributors, liquid and solid contaminants are still commonly found within natural gas pipelines. As such, a need exists for real-time detection of these contaminants, within natural gas pipelines, in order to determine contaminant sources and reduce contaminant quantities. In this study, an in-line, non-perturbing, real-time, microwave-based contaminants sensing technology was developed and tested at a natural gas test facility located in Alberta, Canada. The contaminants detector was installed on DN150 pipe and tested over a gas velocity range of 1.3–13.2 m/s. First, glass oxide particles were intermittently injected into the gas stream immediately upstream of the detector. Two different glass oxide particles were tested with particle diameter ranges of 44–88 μm and 88–149μm. Second, liquid contaminant, in the form of compressor lubrication oil, was atomized into the gas stream immediately upstream of the detector. Three types of atomizing nozzles were used in conjunction with liquid injection pumps to test liquid injection rates in the range of 0.07–0.7 L/min. Liquid and solid contaminants were successfully detected using the standard deviation of in-phase and quadrature baseband voltage measurements from the contaminants detector. This paper quantitatively evaluates the solid/liquid contaminants detection performance of this detector in the context of natural gas pipeline applications.

Volume 3: Operations, Monitoring, and Maintenance; Materials and Joining
Khalifa University of Science and Technology (AE), Nova Chemicals (Canada) (CA)
Openalex Percentile: Top 50%
Advanced Chemical Sensor Technologies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.