Thermal Energy and Exergy Analysis of Asphalt Solar Water Heater for Small Residences

The objective of this research is to study the energy efficiency and exertion of asphalt solar water heaters (ASWH) in transmitting solar heat through water pipes together with friction and energy destruction. One ASWH had a water flow rate of 0.02 kg/s, whereas the other had a flow rate of 0.04 kg/s. Each ASWH has a surface area of 0.5 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, The asphalt has copper pipes buried 10 mm deep. Placed facing south at an angle of 13.5 degrees. The results shown that, the water flow rate 0.04 kg/s has relatively high the energy and exergy efficiencies. The energy and exergy efficiencies were changed from 28% to 60% and 3.2% to 11 %, respectively, depending on the water flow rate, asphalt temperature, and sun intensity. The water flow rate is important in estimating the internal convection coefficient and the Reynolds number for determining the friction effect in copper pipes varies with internal convection. The friction factors cause pressure loss and the exergy destruction caused by friction.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/ri2c64012.2024.10784411
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Energy and Exergy Analysis of Asphalt Solar Water Heater for Small Residences

Thana Ananacha, Onvalee Amornleetrakul
Solar Thermal and Photovoltaic Systems
article

Thermal Energy and Exergy Analysis of Asphalt Solar Water Heater for Small Residences

Thana Ananacha, Onvalee Amornleetrakul
article en

Abstract

The objective of this research is to study the energy efficiency and exertion of asphalt solar water heaters (ASWH) in transmitting solar heat through water pipes together with friction and energy destruction. One ASWH had a water flow rate of 0.02 kg/s, whereas the other had a flow rate of 0.04 kg/s. Each ASWH has a surface area of 0.5 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, The asphalt has copper pipes buried 10 mm deep. Placed facing south at an angle of 13.5 degrees. The results shown that, the water flow rate 0.04 kg/s has relatively high the energy and exergy efficiencies. The energy and exergy efficiencies were changed from 28% to 60% and 3.2% to 11 %, respectively, depending on the water flow rate, asphalt temperature, and sun intensity. The water flow rate is important in estimating the internal convection coefficient and the Reynolds number for determining the friction effect in copper pipes varies with internal convection. The friction factors cause pressure loss and the exergy destruction caused by friction.

King Mongkut's University of Technology North Bangkok (TH)
Openalex Percentile: Top 86%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.