Enhanced Non-Contact Vital Sign Monitoring via Depth Camera-assisted Millimeter-Wave Radar

Non-contact vital sign monitoring with mmWave radar has been regarded as an effective method for identifying lung and heart diseases due to its strong penetration and non-invasive capabilities. Nevertheless, relying solely on millimeter-wave radar for vital sign monitoring is susceptible to interference from multipath reflections, which degrades the measurement accuracy. To address this issue and enhance measurement accuracy, we propose a system design that leverages the depth camera for precise target location and subsequently employs dynamic beamforming techniques to effectively monitor the specified region. The experimental results demonstrate that our proposed system achieves an average error of 2.44 beats per minute (BPM) for heart rate monitoring and 0.22 breaths per minute (BPM) for respiratory rate monitoring. Compared to systems without beamforming, our system reduces the mean error for heart rate monitoring by 4.21 BPM and for respiratory rate monitoring by 0.51 BPM.

Authors

Institutions

Publication Details

Published
2024-10-17
DOI
https://doi.org/10.1109/aiotsys63104.2024.10780533
Primary Topic
Traumatic Ocular and Foreign Body Injuries
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Non-Contact Vital Sign Monitoring via Depth Camera-assisted Millimeter-Wave Radar

Zhiguo Shi, Rongxing Lu, Chenglong Dou, Liping Qian et al.
Traumatic Ocular and Foreign Body Injuries
article

Enhanced Non-Contact Vital Sign Monitoring via Depth Camera-assisted Millimeter-Wave Radar

Zhiguo Shi, Rongxing Lu, Chenglong Dou, Liping Qian, Yuan Wu, Yucheng Liu, Hanwen Zhang
article en

Abstract

Non-contact vital sign monitoring with mmWave radar has been regarded as an effective method for identifying lung and heart diseases due to its strong penetration and non-invasive capabilities. Nevertheless, relying solely on millimeter-wave radar for vital sign monitoring is susceptible to interference from multipath reflections, which degrades the measurement accuracy. To address this issue and enhance measurement accuracy, we propose a system design that leverages the depth camera for precise target location and subsequently employs dynamic beamforming techniques to effectively monitor the specified region. The experimental results demonstrate that our proposed system achieves an average error of 2.44 beats per minute (BPM) for heart rate monitoring and 0.22 breaths per minute (BPM) for respiratory rate monitoring. Compared to systems without beamforming, our system reduces the mean error for heart rate monitoring by 4.21 BPM and for respiratory rate monitoring by 0.51 BPM.

University of New Brunswick (CA), University of Macau (MO), Zhejiang University of Technology (CN), City University of Macau (MO), Zhejiang University (CN)
National Natural Science Foundation of China, Fundo para o Desenvolvimento das Ciências e da Tecnologia, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 63%
Traumatic Ocular and Foreign Body Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Non-Contact Vital Sign Monitoring via Depth Camera-assisted Millimeter-Wave Radar — Zhiguo Shi, Rongxing Lu, et al. · (2024) | TGRS Research Map | TGRS