Full-Scale Burst Tests With Hydrogen

Abstract Five full-scale burst tests in hydrogen and four in water have been conducted on nominally identical pairs of vessels containing nominally identical defects to investigate the effect of hydrogen on the burst strength of defects in pipelines. A short section of line pipe cut from a pipeline commissioned in 1969 was used to fabricate the test vessels. The line pipe has a nominal diameter equal to 609.6 mm (24 in.) and a nominal wall thickness equal to 11.91 mm. It is Grade X52. It has a longitudinal seam weld. Five different types of defects were tested in the burst tests: an internal and external, sharp, part-through-wall defect (the internal defect was only tested in hydrogen); an external, blunt part-through-wall defect; a plain dent; and a dent and gouge (a notch). The part-through-wall defects were longitudinally orientated. The defects were all in the pipe body. The blunt and sharp, part-through-wall defects had nominally identical depths and lengths. The failure pressures of the external, blunt and sharp, part-through-wall defects, plain dents and smooth dents and gouges (notches) in hydrogen and in water were similar. The failure pressures of the internal, sharp, part-through-wall defect in hydrogen was significantly lower than that of the external defect in hydrogen and in water.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.1115/ipc2024-131285
Citations
2
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-Scale Burst Tests With Hydrogen

Andrew Cosham, Clara Huéscar Medina, Gemma Simpson, Gary Senior et al.
2 citations
Drilling and Well Engineering
0.67
article

Full-Scale Burst Tests With Hydrogen

Andrew Cosham, Clara Huéscar Medina, Gemma Simpson, Gary Senior, Max Koronka
article en
2 citations

Abstract

Abstract Five full-scale burst tests in hydrogen and four in water have been conducted on nominally identical pairs of vessels containing nominally identical defects to investigate the effect of hydrogen on the burst strength of defects in pipelines. A short section of line pipe cut from a pipeline commissioned in 1969 was used to fabricate the test vessels. The line pipe has a nominal diameter equal to 609.6 mm (24 in.) and a nominal wall thickness equal to 11.91 mm. It is Grade X52. It has a longitudinal seam weld. Five different types of defects were tested in the burst tests: an internal and external, sharp, part-through-wall defect (the internal defect was only tested in hydrogen); an external, blunt part-through-wall defect; a plain dent; and a dent and gouge (a notch). The part-through-wall defects were longitudinally orientated. The defects were all in the pipe body. The blunt and sharp, part-through-wall defects had nominally identical depths and lengths. The failure pressures of the external, blunt and sharp, part-through-wall defects, plain dents and smooth dents and gouges (notches) in hydrogen and in water were similar. The failure pressures of the internal, sharp, part-through-wall defect in hydrogen was significantly lower than that of the external defect in hydrogen and in water.

DNV (Norway) (NO), Blue Planet (Norway) (NO), Line Corporation (Japan) (JP)
Openalex Percentile: Top 29%
Drilling and Well Engineering
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.