Inversion of the temperature field in oil‐immersed reactors using optimal measurement points selected by random forest

Abstract To address the subjective issue of selecting measurement points based on mainstream line methods for hotspot temperature inversion in oil‐immersed power equipment, this paper demonstrates an oil‐immersed reactor temperature field inversion method based on random forest (RF) measurement point optimisation. Firstly, a temperature field calculation method for a 22‐kV oil‐immersed reactor is proposed. In combination with Latin hypercube sampling, 50 sets of temperature field data are calculated. Based on these samples, the selection of measurement points based on RF feature importance and the training of the genetic algorithm‐optimised back propagation (GA‐BP) inversion model are undertaken. Finally, the optimal combination of external tank wall measurement points is determined based on comprehensive error indicators, achieving accurate inversion of internal hotspot temperatures in the reactor (with an error of 0.243 °C). The inversion errors are reduced by 2.91 °C and 1.47 °C on average per group compared to existing methods, evincing the superiority of the proposed model.

Authors

Institutions

Publication Details

Journal
IET Electric Power Applications
Published
2024-12-13
DOI
https://doi.org/10.1049/elp2.12532
Citations
2
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inversion of the temperature field in oil‐immersed reactors using optimal measurement points selected by random forest

Fangcheng Lv, Xiaopeng Li, Jiayi Guo, Yunpeng Liu et al.
2 citations
IET Electric Power Applications
Power Transformer Diagnostics and Insulation
0.42
article

Inversion of the temperature field in oil‐immersed reactors using optimal measurement points selected by random forest

Fangcheng Lv, Xiaopeng Li, Jiayi Guo, Yunpeng Liu, Jingyun Zhao, Kailin Zhu
article en
2 citations

Abstract

Abstract To address the subjective issue of selecting measurement points based on mainstream line methods for hotspot temperature inversion in oil‐immersed power equipment, this paper demonstrates an oil‐immersed reactor temperature field inversion method based on random forest (RF) measurement point optimisation. Firstly, a temperature field calculation method for a 22‐kV oil‐immersed reactor is proposed. In combination with Latin hypercube sampling, 50 sets of temperature field data are calculated. Based on these samples, the selection of measurement points based on RF feature importance and the training of the genetic algorithm‐optimised back propagation (GA‐BP) inversion model are undertaken. Finally, the optimal combination of external tank wall measurement points is determined based on comprehensive error indicators, achieving accurate inversion of internal hotspot temperatures in the reactor (with an error of 0.243 °C). The inversion errors are reduced by 2.91 °C and 1.47 °C on average per group compared to existing methods, evincing the superiority of the proposed model.

IET Electric Power ApplicationsVol. 19(1)
North China Electric Power University (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
Life in Land
Openalex Percentile: Top 36%
Power Transformer Diagnostics and Insulation
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.