A way to measure the target contrast in low light level based on image intensifier technology

Target contrast is an important factor that affects the accuracy of viewing distance evaluation result of low light level device. There is a great difference between night sky spectrum and day spectrum, and the contrast of night target is different from that of day, so it is very important to measure the night target contrast accurately. Based on the basic concept of contrast and the relationship between brightness and illumination, and according to the high matching between the spectral response characteristic of the 3rd image intensifier and starlight spectrum, the way to measure the night target contrast by image intensified CMOS is proposed in this paper. And a measuring device calibrated by standard light source of 2856K color temperature in the laboratory is founded. Then, the device calibrated is used to measure the target contrast in urban. The results show that the deviation of the target contrast measuring device based on image intensified CMOS is less than 6.5% after laboratory calibration, the target contrast measurement results in urban are consistent with the visual observation results, and the target contrast measurement results are reliable. The results in this paper can provide an effective measurement method to ensure the accuracy of viewing distance evaluation results of low light level device.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1117/12.3046226
Primary Topic
Impact of Light on Environment and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A way to measure the target contrast in low light level based on image intensifier technology

Zhiqiang Hu, Zhiwei ZUO, Qin Zhang, Xiaofeng Bai et al.
Impact of Light on Environment and Health
article

A way to measure the target contrast in low light level based on image intensifier technology

Zhiqiang Hu, Zhiwei ZUO, Qin Zhang, Xiaofeng Bai, Feng Shi, Songzhou Yan
article en

Abstract

Target contrast is an important factor that affects the accuracy of viewing distance evaluation result of low light level device. There is a great difference between night sky spectrum and day spectrum, and the contrast of night target is different from that of day, so it is very important to measure the night target contrast accurately. Based on the basic concept of contrast and the relationship between brightness and illumination, and according to the high matching between the spectral response characteristic of the 3rd image intensifier and starlight spectrum, the way to measure the night target contrast by image intensified CMOS is proposed in this paper. And a measuring device calibrated by standard light source of 2856K color temperature in the laboratory is founded. Then, the device calibrated is used to measure the target contrast in urban. The results show that the deviation of the target contrast measuring device based on image intensified CMOS is less than 6.5% after laboratory calibration, the target contrast measurement results in urban are consistent with the visual observation results, and the target contrast measurement results are reliable. The results in this paper can provide an effective measurement method to ensure the accuracy of viewing distance evaluation results of low light level device.

Guangzhou Electronic Technology (China) (CN), Institute of Physics (CN)
Openalex Percentile: Top 80%
Impact of Light on Environment and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.